{"product_id":"cummins-400-amp-3ph-automatic-transfer-switch","title":"Cummins OTEC 400 Amp NSE 208V 3ph Automatic Transfer Switches - A075F130","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"font-family: 'Segoe UI', Arial, sans-serif; max-width: auto; margin: 0 auto; color: #333; line-height: 1.6;\"\u003e\n\n\u003c!-- Dark Header Banner --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 35px 40px; border-radius: 8px 8px 0 0; text-align: center;\"\u003e\n\u003ch2 style=\"color: #ffffff; font-size: 28px; font-weight: bold; margin: 0 0 12px 0;\"\u003eCummins OTEC 400A 208V 3-Phase Open Transition Automatic Transfer Switch\u003c\/h2\u003e\n\u003cp style=\"color: #b8c7d6; font-size: 16px; margin: 0;\"\u003eA075F130 | Open Transition | 400 Amps | NEMA 3R | 208V System Voltage\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Stats Boxes - 3 Columns --\u003e\n\u003cdiv style=\"display: flex; justify-content: space-between; gap: 0; margin: 0; border: 2px solid #d0d0d0; border-top: none;\"\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e400A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eCurrent Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e208V\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eVoltage Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e3Ph\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003ePhase Type\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Product Overview --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.8;\"\u003eThe Cummins automatic transfer switch A075F130 ensures reliable power continuity for critical electrical loads. This OTEC model operates as an open transition switch between primary utility power and standby generator sets. It is designed for emergency, legally required, and optional standby applications. The unit features a fully integrated microprocessor controller for practical functionality. LED indicators and digital pushbuttons simplify operator use and status monitoring. Heavy-duty silver alloy contacts handle motor loads without routine maintenance. The switch monitors both power sources to signal generator startup automatically. It transfers power instantly when utility fails and returns load once stable utility is available. Large generator items like this switch often have extended lead times. Customers must confirm voltage, amperage, enclosure, freight, and lead time with PES before ordering. This ensures perfect compatibility with your specific backup power system requirements. The NEMA 3R enclosure provides protection against rain and sleet for outdoor installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Key Benefits --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eMicroprocessor Control:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eStandard control features an easy-to-use interface with LED status displays and pushbuttons for tests and exercise timing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eOpen Transition Safety:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eProgrammed transition completely disconnects the load from both sources to meet NEMA MG-1 recommendations for inductive loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eFrictionless Mechanism:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eA unique bi-directional linear actuator provides constant force and straight-line action during automatic operation without friction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eManual Operation Ready:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eShielded termination and over-center contact mechanisms allow effective manual operation under deenergized conditions when needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003ePositive Interlocking:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eMechanical and electrical interlocks prevent source-to-source connection through power or control wiring to ensure safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- How It Works --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eHow It Works\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 20px 0; line-height: 1.8;\"\u003eThe Cummins OTEC transfer switch continuously monitors both utility power and generator set status. When utility power is interrupted, the controller signals the generator set to start immediately. The switch then automatically transfers the electrical load to the standby generator source. This process ensures that critical equipment remains powered during utility failures without interruption. Once a stable utility source is detected again, the system returns the load to the primary power source. The fully integrated controller manages these transitions with precise timing and safety interlocks. This break-before-make action prevents any momentary connection between the two power sources. The system is designed for reliable operation in emergency and legally required standby applications.\u003c\/p\u003e\n\u003c!-- Repeat for each mechanism (min 3 - each detail min 2 sentences) --\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eAutomatic Power Transfer:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe switch monitors both power sources and signals generator startup automatically when utility fails. It transfers power to the generator and returns load to utility once stable power is available.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eProgrammed Transition Timing:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eOpen transition timing can be adjusted to completely disconnect the load from both sources for a set period. This meets NEMA MG-1 recommendations for safely transferring inductive loads like motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eBreak-Before-Make Action:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eIndependent break-before-make action is used for both 3-pole and 4-pole switches with switched neutral. This design allows sync check operation when required for proper motor and rectifier load transfer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Technical Specifications --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eA075F130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eOTEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e400 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e208V (120\/208V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003ePhase Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eTransition Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eOpen Transition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNEMA 3R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e59.0 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e27.5 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e16.5 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e425 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eMax Voltage Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eContinuous Load Limit\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e100% of switch rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eTungsten Load Limit\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e30% of switch rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- Certifications \u0026 Warranty --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff; border-left: 4px solid #1e3a5f;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0;\"\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eCertifications:\u003c\/span\u003e NEMA MG-1 Compliant, NEMA 3R Enclosure Rated\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eInverter Compatibility:\u003c\/span\u003e Suitable for emergency, legally required, and optional standby mode applications\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eEnvironmental:\u003c\/span\u003e Protected against rain and sleet for outdoor installation\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eWarranty:\u003c\/span\u003e Comprehensive warranty backed by a worldwide network of distributors with factory-trained service technicians\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Documentation --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eDocumentation\u003c\/h2\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid rgb(30, 58, 95); border-radius: 6px; background-color: #ffffff;\"\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/OTEC_ATS_Spec_Sheet_2.pdf?v=1784205331\" target=\"_blank\" rel=\"noopener\"\u003eProduct Datasheet (PDF)\u003c\/a\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003c!-- Lead Time --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 24px 40px; margin-top: 24px; border-radius: 6px; text-align: center;\"\u003e\n\u003cp style=\"margin: 0; color: #ffffff; font-size: 16px;\"\u003e\u003cspan style=\"font-weight: bold; color: #4ade80;\"\u003e● Available\u003c\/span\u003e \u003cspan style=\"margin: 0 16px; color: #7a9cc7;\"\u003e|\u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eContact us for lead time and pricing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Cummins","offers":[{"title":"Default Title","offer_id":41763022733446,"sku":"PES-PA-ELC-1483","price":6139.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/Automatic_Transfer_Switch.png?v=1763655533","url":"https:\/\/www.portlandiaelectric.supply\/products\/cummins-400-amp-3ph-automatic-transfer-switch","provider":"Portlandia Electric Supply","version":"1.0","type":"link"}