{"product_id":"cummins-otec-125-amp-nse","title":"Cummins OTEC 125 Amp NSE 208V 3ph Automatic Transfer Switches - A075F124","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"font-family: 'Segoe UI', Arial, sans-serif; max-width: auto; margin: 0 auto; color: #333; line-height: 1.6;\"\u003e\n\n\u003c!-- Dark Header Banner --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 35px 40px; border-radius: 8px 8px 0 0; text-align: center;\"\u003e\n\u003ch2 style=\"color: #ffffff; font-size: 28px; font-weight: bold; margin: 0 0 12px 0;\"\u003eCummins OTEC 125 Amp NSE 208V 3-Phase Automatic Transfer Switch A075F124\u003c\/h2\u003e\n\u003cp style=\"color: #b8c7d6; font-size: 16px; margin: 0;\"\u003eModel A075F124 | Open Transition | 125 Amp | Non-Service Entrance | 208V System Voltage\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Stats Boxes - 3 Columns --\u003e\n\u003cdiv style=\"display: flex; justify-content: space-between; gap: 0; margin: 0; border: 2px solid #d0d0d0; border-top: none;\"\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e125 Amps\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eMax Current Capacity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e208V\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eVoltage Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e3-Phase\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003ePhase Configuration\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Product Overview --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.8;\"\u003eThe Cummins OTEC 125 Amp NSE (Non-Service Entrance) 208V 3-phase \u003ca href=\"https:\/\/www.portlandiaelectric.supply\/collections\/automatic-transfer-switches-generator-accessories\" target=\"_blank\" title=\"\" rel=\"noopener\"\u003eAutomatic Transfer Switch \u003c\/a\u003e(ATS) is engineered for commercial and industrial facilities requiring reliable backup power. This robust unit ensures seamless, automatic switching between utility power and backup generator sources during outages. With a 125 Amp capacity, it supports critical systems without interruption. The 3-phase 208V configuration delivers balanced \u003ca href=\"https:\/\/share.google\/iE0LaxmqMy3eith0g\" target=\"_blank\" title=\"\" rel=\"noopener\"\u003eenergy\u003c\/a\u003e distribution across connected loads. Its NSE-rated design offers flexibility for installations where service entrance capability is unnecessary. This switch is ideal for emergency, legally required, and optional standby applications. It features a microprocessor-based controller for precise monitoring and control. LED indicators and digital pushbuttons simplify operator interaction. The open-transition mechanism ensures safe break-before-make operation. Heavy-duty silver alloy contacts handle high-endurance switching reliably. UL 1008 listed and NEC compliant, it meets top safety standards. Durable construction ensures long-term operational stability in demanding environments.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Key Benefits --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eSeamless Power Transfer:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eAutomatic switching ensures uninterrupted power for critical commercial systems during utility failures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eBalanced Load Distribution:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe 3-phase 208V design provides efficient, stable power distribution for high-demand industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eNSE Design Flexibility:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eNon-Service Entrance rating simplifies installation where utility-to-load switching is not required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eAdvanced Microprocessor Control:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003ePowerCommand 40 controller offers precise monitoring, voltage sensing, and configurable exerciser scheduling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eSafety and Compliance:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eUL 1008 listed and NEC compliant, ensuring reliable operation under strict safety regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- How It Works --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eHow It Works\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 20px 0; line-height: 1.8;\"\u003eThe Cummins OTEC Automatic Transfer Switch continuously monitors both primary utility power and standby generator voltage. When utility power fails or drops below a set threshold, the controller signals the generator to start. Once the generator reaches stable operating voltage, the switch automatically transfers the electrical load. This open-transition process ensures a break-before-make sequence, completely disconnecting the load from both sources briefly. This prevents dangerous source-to-source connections. After utility power stabilizes, the switch returns the load to the primary source. The microprocessor controller manages timing, voltage imbalance sensing, and phase rotation detection. LED displays provide real-time status updates for operators. Manual operation handles are available for deenergized conditions if needed.\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003ePower Monitoring:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe integrated controller constantly evaluates both power sources for voltage stability and frequency. It detects failures instantly and triggers generator startup signals automatically.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eOpen Transition Transfer:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe bi-directional linear actuator moves contacts in a break-before-make sequence. This disconnects the load from both sources for a programmed time, ensuring safe transfer for inductive loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eReturn to Utility:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eOnce stable utility power is confirmed, the switch reverses the process. It transfers the load back to the primary source and allows the generator to cool down before shutdown.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Technical Specifications --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eMPN\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eA075F124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eVendor\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eCummins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eAmperage\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e125 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e120\/208V AC at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003ePhase Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003ePoles\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e4-Pole (Switched Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eTransfer Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eAutomatic Open Transition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eService Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNon-Service Entrance (NSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eController\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003ePowerCommand 40 Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eLCD with LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eTransfer Time\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e≤ 6 Cycles (60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNEMA 1 (Indoor) \/ NEMA 3R (Outdoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eContact Material\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eHeavy-Duty Silver Alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eArc Chutes\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eMulti-Leaf Arc Chutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eManual Operation\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eYes (Deenergized Conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eCummins Backup Generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- Certifications \u0026 Warranty --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff; border-left: 4px solid #1e3a5f;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0;\"\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eCertifications:\u003c\/span\u003e UL 1008 Listed, CSA Standards, NEMA MG-1 Compliant\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eInverter Compatibility:\u003c\/span\u003e Compatible with Cummins Backup Generator Sets\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eEnvironmental:\u003c\/span\u003e NEC and NFPA Requirements Met, NEMA 1\/3R Enclosure\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eWarranty:\u003c\/span\u003e Cummins 1-Year Limited Warranty with Worldwide Distributor Support\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Documentation --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eDocumentation\u003c\/h2\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid rgb(30, 58, 95); border-radius: 6px; background-color: #ffffff; margin-bottom: 10px; margin-right: 10px;\"\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/S-1639_OTEC_SPEC_C.pdf?v=1784196696\" target=\"_blank\" rel=\"noopener\"\u003eOTEC Spec (PDF)\u003c\/a\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid rgb(30, 58, 95); border-radius: 6px; background-color: #ffffff; margin-bottom: 10px; margin-right: 10px;\"\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/OTEC_ATS_Spec_Sheet.pdf?v=1784197030\" target=\"_blank\" rel=\"noopener\"\u003eSpec Sheet (PDF)\u003c\/a\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid rgb(30, 58, 95); border-radius: 6px; background-color: #ffffff; margin-bottom: 10px; margin-right: 10px;\"\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/OTEC_125_outline_dwg.pdf?v=1784197030\" target=\"_blank\" rel=\"noopener\"\u003eOutline Dwg (PDF)\u003c\/a\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003c!-- Lead Time --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 24px 40px; margin-top: 24px; border-radius: 6px; text-align: center;\"\u003e\n\u003cp style=\"margin: 0; color: #ffffff; font-size: 16px;\"\u003e\u003cspan style=\"font-weight: bold; color: #4ade80;\"\u003e● Available\u003c\/span\u003e \u003cspan style=\"margin: 0 16px; color: #7a9cc7;\"\u003e|\u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eContact us for lead time and pricing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Cummins","offers":[{"title":"Default Title","offer_id":41763016278150,"sku":"PES-PA-ELC-1472","price":3803.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/A075F124-1-1.png?v=1758195953","url":"https:\/\/www.portlandiaelectric.supply\/products\/cummins-otec-125-amp-nse","provider":"Portlandia Electric Supply","version":"1.0","type":"link"}