{"product_id":"cummins-otec-125-amp","title":"Cummins OTEC 125 Amp NSE 480V 3ph Automatic Transfer Switches - A075F125","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"font-family: 'Segoe UI', Arial, sans-serif; max-width: auto; margin: 0 auto; color: #333; line-height: 1.6;\"\u003e\n\n\u003c!-- Dark Header Banner --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 35px 40px; border-radius: 8px 8px 0 0; text-align: center;\"\u003e\n\u003ch2 style=\"color: #ffffff; font-size: 28px; font-weight: bold; margin: 0 0 12px 0;\"\u003eCummins OTEC 125 Amp NSE 480V 3-Phase Automatic Transfer Switch\u003c\/h2\u003e\n\u003cp style=\"color: #b8c7d6; font-size: 16px; margin: 0;\"\u003eA075F125 | PowerCommand 40 Microprocessor | 4-Pole Switched Neutral | Non-Bifacial | 480V System Voltage\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Stats Boxes - 3 Columns --\u003e\n\u003cdiv style=\"display: flex; justify-content: space-between; gap: 0; margin: 0; border: 2px solid #d0d0d0; border-top: none;\"\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e125 Amps\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eRated Capacity\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e480V\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eVoltage Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003eOpen Transition\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eTransfer Type\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Product Overview --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.8;\"\u003eThe Cummins OTEC 125 Amp NSE (Non-Service Entrance) 480V 3-phase \u003ca href=\"https:\/\/www.portlandiaelectric.supply\/collections\/automatic-transfer-switches-generator-accessories\" target=\"_blank\" title=\"\" rel=\"noopener\"\u003eAutomatic Transfer Switch \u003c\/a\u003e(ATS) is engineered for demanding commercial and industrial backup power needs. This robust unit ensures continuous operation by automatically shifting electrical loads from utility power to a backup generator during grid failures. Its 125 Amp capacity supports critical systems in high-demand environments effectively. The 480V 3-phase setup delivers balanced \u003ca href=\"https:\/\/share.google\/iE0LaxmqMy3eith0g\" target=\"_blank\" title=\"\" rel=\"noopener\"\u003eenergy\u003c\/a\u003e distribution across all phases. The NSE-rated design allows flexible installation where service entrance is not required. UL 1008 listing and NEC compliance guarantee top safety and reliability standards. Durable construction ensures long-term, reliable operation under stress. This switch is ideal for businesses requiring minimal downtime during outages. Seamless integration with Cummins backup generators enhances overall system performance. Reliable switching protects valuable infrastructure from power interruptions.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Key Benefits --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eSeamless Power Transfer:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eAutomatic switching ensures uninterrupted power for critical systems during utility outages.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eBalanced Distribution:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe 480V 3-phase configuration provides efficient and balanced power across all lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eFlexible Installation:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eNon-Service Entrance (NSE) rating allows versatile placement options in various facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eAdvanced Control:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003ePowerCommand 40 microprocessor control with LCD display simplifies monitoring and testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eSafety Certified:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eUL 1008 listed and NEC compliant for guaranteed safety and regulatory adherence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- How It Works --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eHow It Works\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 20px 0; line-height: 1.8;\"\u003eThis Cummins OTEC ATS continuously monitors both utility and generator power sources to ensure reliability. When the utility grid fails, the switch signals the generator to start immediately. Once the generator reaches stable voltage, the ATS transfers the load automatically. The system uses an open transition, break-before-make action to prevent source-to-source connection. This ensures the load is completely disconnected from both sources briefly during transfer. Once utility power stabilizes, the switch returns the load to the primary source seamlessly. The integrated controller manages all timing and testing functions automatically for ease of use.\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003ePower Monitoring:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe microprocessor controller constantly checks voltage levels on both utility and generator inputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eGenerator Start Signal:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eUpon detecting a utility outage, the switch sends a startup signal to the backup generator.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eOpen Transition Transfer:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe bi-directional linear actuator disconnects the load before connecting it to the backup source.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Technical Specifications --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eA075F125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eVendor\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eCummins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e125 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e277\/480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003ePhase Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e3-Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003ePole Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e4-Pole (Switched Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eTransfer Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eOpen Transition (Break-Before-Make)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eService Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNon-Service Entrance (NSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNEMA 1 (Indoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eController Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003ePowerCommand 40 Microprocessor with LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eContact Material\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eHeavy-Duty Silver Alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eMax Utility Input\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e125 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eMax Generator Input\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e125 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eCummins Onan Liquid Cooled Standby Generators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- Certifications \u0026 Warranty --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff; border-left: 4px solid #1e3a5f;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0;\"\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eCertifications:\u003c\/span\u003e UL 1008 Listed, CSA Standards Compliant\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eInverter Compatibility:\u003c\/span\u003e Designed for Cummins Backup Generators\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eEnvironmental:\u003c\/span\u003e NEC and NFPA Standards Compliant\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eWarranty:\u003c\/span\u003e Cummins Standard 1-Year Limited Warranty with worldwide support\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Documentation --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eDocumentation\u003c\/h2\u003e\n\u003cdiv style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid rgb(30, 58, 95); border-radius: 6px; background-color: #ffffff; margin-bottom: 12px;\"\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/S-1639_OTEC_SPEC_C.pdf?v=1784196696\" target=\"_blank\" rel=\"noopener\" style=\"text-decoration: none; color: #1e3a5f;\"\u003eS-1639 OTEC SPEC C\u003c\/a\u003e\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid rgb(30, 58, 95); border-radius: 6px; background-color: #ffffff; margin-bottom: 12px;\"\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/OTEC_ATS_Spec_Sheet.pdf?v=1784197030\" target=\"_blank\" rel=\"noopener\" style=\"text-decoration: none; color: #1e3a5f;\"\u003eOTEC ATS Spec Sheet\u003c\/a\u003e\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid rgb(30, 58, 95); border-radius: 6px; background-color: #ffffff; margin-bottom: 12px;\"\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/OTEC_125_outline_dwg.pdf?v=1784197030\" target=\"_blank\" rel=\"noopener\" style=\"text-decoration: none; color: #1e3a5f;\"\u003eOTEC 125 Outline DWG\u003c\/a\u003e\u003c\/b\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Lead Time --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 24px 40px; margin-top: 24px; border-radius: 6px; text-align: center;\"\u003e\n\u003cp style=\"margin: 0; color: #ffffff; font-size: 16px;\"\u003e\u003cspan style=\"font-weight: bold; color: #4ade80;\"\u003e● Available\u003c\/span\u003e \u003cspan style=\"margin: 0 16px; color: #7a9cc7;\"\u003e|\u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eContact us for lead time and pricing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Cummins","offers":[{"title":"Default Title","offer_id":41763016933510,"sku":"PES-PA-ELC-1473","price":2851.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/A075F125-1-1.png?v=1758195954","url":"https:\/\/www.portlandiaelectric.supply\/products\/cummins-otec-125-amp","provider":"Portlandia Electric Supply","version":"1.0","type":"link"}