{"product_id":"cummins-otec-400-amp-nse-240v-3ph-automatic-transfer-switche","title":"Cummins OTEC 400 Amp NSE 240V 3ph Automatic Transfer Switches - A075F131","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"font-family: 'Segoe UI', Arial, sans-serif; max-width: auto; margin: 0 auto; color: #333; line-height: 1.6;\"\u003e\n\n\u003c!-- Dark Header Banner --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 35px 40px; border-radius: 8px 8px 0 0; text-align: center;\"\u003e\n\u003ch2 style=\"color: #ffffff; font-size: 28px; font-weight: bold; margin: 0 0 12px 0;\"\u003eCummins OTEC A075F131 400A 240V 3-Phase Automatic Transfer Switch\u003c\/h2\u003e\n\u003cp style=\"color: #b8c7d6; font-size: 16px; margin: 0;\"\u003eA075F131 | Open Transition | 400 Amp | 3-Phase | 240V System Voltage\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Stats Boxes - 3 Columns --\u003e\n\u003cdiv style=\"display: flex; justify-content: space-between; gap: 0; margin: 0; border: 2px solid #d0d0d0; border-top: none;\"\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e400A\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eMax Amp Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e240V\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eVoltage Rating\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 28px 20px; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 32px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e3Ph\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003ePhase Count\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Product Overview --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.8;\"\u003eThe \u003cb\u003eCummins automatic transfer switch A075F131\u003c\/b\u003e delivers reliable backup power management for commercial and light industrial sites. This OTEC model features a robust 400-amp capacity and operates at 240 volts across three phases. It is designed to switch electrical loads between primary utility power and standby generator sets seamlessly. The unit includes an updated PowerCommand 40-11 control system for precise monitoring and operation. Its NEMA 3R enclosure ensures durability for both indoor and outdoor installations in harsh environments. Heavy-duty silver alloy contacts handle high loads without routine maintenance. This automatic transfer switch is ideal for emergency, legally required, or optional standby applications. PES confirms voltage, freight, and lead time before final order placement to ensure compatibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Key Benefits --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eAdvanced Microprocessor Control:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe PowerCommand 40-11 controller offers easy-to-use standard control with LED status displays and digital pushbuttons.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eRobust NEMA 3R Enclosure:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThis weather-resistant housing protects internal components for safe indoor or outdoor installation in various climates.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eHeavy-Duty Contact System:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eSilver alloy contacts and multi-leaf arc chutes provide dependable arc interruption for motor and total system loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003ePositive Interlocking Safety:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eMechanical and electrical interlocks prevent dangerous source-to-source connections through power or control wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eProgrammed Transition Option:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eOpen transition timing can be adjusted to disconnect loads completely, as recommended by NEMA MG-1 for inductive loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- How It Works --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eHow It Works\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 20px 0; line-height: 1.8;\"\u003eThe Cummins OTEC transfer switch continuously monitors both the primary utility power and the standby generator set. When the utility power fails or becomes unstable, the system automatically signals the generator to start. Once the generator reaches a stable operating state, the switch transfers the electrical load to the generator source. Upon restoration of stable utility power, the switch returns the load to the primary source automatically. This break-before-make action ensures a safe transition by completely disconnecting the load from both sources momentarily. The fully integrated controller manages these sequences with precision using microprocessor technology.\u003c\/p\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eAutomatic Voltage Monitoring:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe system constantly checks voltage levels on both sources to detect faults or instability instantly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eGenerator Start Signal:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eUpon utility failure, the controller sends a signal to start the generator set automatically without manual intervention.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 16px;\"\u003e\n\u003cp style=\"font-weight: bold; color: #1e3a5f;\"\u003eLoad Transfer Mechanism: \u003cspan style=\"color: #444;\"\u003eA bi-directional linear actuator provides friction-free, straight-line transfer action for reliable automatic operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- Technical Specifications --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eA075F131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eModel Series\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eOTEC Spec C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eAmp Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e400 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003ePhase Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e3-Phase (4-Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eControl System\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003ePowerCommand 40-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNEMA 3R (Indoor\/Outdoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eTransition Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eOpen Transition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e-30°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eTransfer Time\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eMax 6 cycles at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eService Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNot Service Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eUL-1008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- Certifications \u0026 Warranty --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff; border-left: 4px solid #1e3a5f;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0;\"\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eCertifications:\u003c\/span\u003e UL-1008, UL\/CSA Listed\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eInverter Compatibility:\u003c\/span\u003e Compatible with Cummins Onan Liquid Cooled Standby Generators\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eEnvironmental:\u003c\/span\u003e NEMA 3R rated for indoor\/outdoor use; Surge withstand per IEEE C62.41\u003cbr\u003e\n\u003cspan style=\"font-weight: 600;\"\u003eWarranty:\u003c\/span\u003e Comprehensive 1-Year Limited Warranty from Cummins Inc.\n\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- Documentation --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eDocumentation\u003c\/h2\u003e\n\u003cspan style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid rgb(30, 58, 95); border-radius: 6px; background-color: #ffffff;\"\u003e\n\u003cb\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/OTEC_ATS_Spec_Sheet_2.pdf?v=1784205331\" target=\"_blank\" rel=\"noopener\"\u003eProduct Datasheet (PDF)\u003c\/a\u003e\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003c!-- Lead Time --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 24px 40px; margin-top: 24px; border-radius: 6px; text-align: center;\"\u003e\n\u003cp style=\"margin: 0; color: #ffffff; font-size: 16px;\"\u003e\u003cspan style=\"font-weight: bold; color: #4ade80;\"\u003e● Available\u003c\/span\u003e \u003cspan style=\"margin: 0 16px; color: #7a9cc7;\"\u003e|\u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eContact PES for lead time, freight, and compatibility confirmation before ordering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Cummins","offers":[{"title":"Default Title","offer_id":41763023093894,"sku":"PES-PA-ELC-1484","price":6139.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/A075F131-1-1.png?v=1758195966","url":"https:\/\/www.portlandiaelectric.supply\/products\/cummins-otec-400-amp-nse-240v-3ph-automatic-transfer-switche","provider":"Portlandia Electric Supply","version":"1.0","type":"link"}