{"product_id":"eg4-gridboss-eg4mid2p200av3-1-microgrid-interconnect-device","title":"EG4 GridBOSS EG4MID2P200AV3.1 Microgrid Interconnect Device","description":"\u003c!-- EG4 GridBOSS Microgrid Interconnect Device EG4MID2P200AV3.1 - Shopify Product Description --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- Copy everything below into your Shopify product description editor --\u003e\n\u003cdiv style=\"font-family: 'Segoe UI', Arial, sans-serif; max-width: auto; margin: 0 auto; color: #333; line-height: 1.6;\"\u003e\n\n  \u003c!-- Dark Header Banner --\u003e\n  \u003cdiv style=\"background-color: #1e3a5f; padding: 35px 40px; border-radius: 8px 8px 0 0; text-align: center;\"\u003e\n    \u003ch2 style=\"color: #ffffff; font-size: 28px; font-weight: bold; margin: 0 0 12px 0; letter-spacing: 0.5px;\"\u003eEG4 GridBOSS Microgrid Interconnect Device (MID)\u003c\/h2\u003e\n    \u003cp style=\"color: #a8c4e0; font-size: 16px; margin: 0; font-weight: 400;\"\u003ePart No. EG4MID2P200AV3.1 | 200A Max | Split-Phase 120\/240Vac | 60Hz | NEMA 3R | Service Entrance Rated | 4 Smart Ports | Breakers Sold Separately\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Stats Boxes - 4 Columns --\u003e\n  \u003cdiv style=\"display: flex; justify-content: space-between; gap: 0; margin: 0; border: 2px solid #d0d0d0; border-top: none;\"\u003e\n    \u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n      \u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e200A\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eService Entrance Rating\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n      \u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e4 Ports\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eSmart \/ AC-Couple Ports\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n      \u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e~25 ms\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eTransfer Time\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; background-color: #ffffff;\"\u003e\n      \u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e10 Yrs\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eStandard Warranty\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Product Overview Section --\u003e\n  \u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eProduct Overview\u003c\/h2\u003e\n    \u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.8;\"\u003eThe \u003cstrong\u003eEG4 GridBOSS Microgrid Interconnect Device\u003c\/strong\u003e (Part No. EG4MID2P200AV3.1) is a 200A split-phase service entrance rated intelligent power distribution device that consolidates up to ten traditionally separate electrical components into a single NEMA 3R enclosure. The GridBOSS replaces the point of common connection, back-fed breakers, feeder taps, tap breakers, supply-side taps, transfer switches, and dedicated combiner panels for grid-in, grid-out, and generator input — functioning as the central interconnection hub for utility power, up to three 90A hybrid inverters, a generator up to 125A (30kW), four programmable smart\/AC-couple ports, and both backed-up and non-backed-up load panels. Designed for 120\/240Vac North American split-phase residential and light commercial applications, the GridBOSS is rated at 200A for both backed-up and non-backed-up loads simultaneously, with a 315A internal bus rating and a 22kAIC interrupt capacity. Breakers for smart ports, hybrid inverter connections, and generator input are sold separately.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Benefits Section --\u003e\n  \u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eKey Benefits\u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eReplaces Up to 10 Separate Components:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe GridBOSS eliminates the need for a separate point of common connection panel, back-fed breakers, feeder taps, tap breakers, supply-side taps, manual transfer switches, and dedicated solar and generator combiner panels — consolidating all of these into one pre-engineered device that is faster to permit, faster to install, and simpler to inspect. EG4 estimates the GridBOSS saves installers up to $7,500 in equipment and labor costs on a typical residential solar-plus-storage project.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003e200A Service Entrance Rated — Backed-Up \u0026amp; Non-Backed-Up Loads:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eUnlike many MID devices that require the homeowner to downsize their service or split loads between separate panels, the GridBOSS maintains a full 200A rating for both backed-up and non-backed-up load buses simultaneously — ensuring no reduction in service capacity after installation and eliminating the need for a separate main distribution panel in most residential applications.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003e4 Programmable Smart \/ AC-Couple Ports:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eFour independently configurable ports — rated at 125A, 80A, 60A, and 60A — can each be individually programmed as a smart load shedding port or an AC-coupling input for grid-tied microinverter strings. Smart load ports allow the system to automatically shed non-critical loads (EV chargers, pool pumps, water heaters) during grid outages or low-battery conditions, extending backup duration without manual intervention.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eSupports Up to Three 90A Hybrid Inverters + 125A Generator:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe GridBOSS provides dedicated connection points for up to three hybrid inverters at up to 90A each — enabling high-capacity multi-inverter parallel systems without external combiner hardware — plus a dedicated generator input rated up to 125A (30kW), with automatic or manual generator control supported through the device's integrated relay logic and five programmable output drivers.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003e~25ms Automatic Transfer — Grid-Forming Microgrid Capability:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eUpon grid outage detection, the GridBOSS isolates the system from utility in approximately 25 milliseconds and signals connected inverters to transition from grid-interactive mode to grid-forming (offline) mode — creating a stable local microgrid from battery and solar resources. This near-seamless transfer time prevents interruption of most sensitive electronic loads and eliminates the need for a separate automatic transfer switch (ATS).\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 0;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003e8-Circuit Energy Monitoring + EG4 App Integration:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eEight onboard energy monitoring circuits provide real-time visibility into power flows across utility input, inverter outputs, generator, and individual load branches — all accessible through the EG4 monitoring app. Five programmable output drivers enable automated control of external contactors, relays, and load management equipment, allowing sophisticated grid-edge automation without additional controllers or gateway hardware.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- How It Works Section --\u003e\n  \u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eHow It Works\u003c\/h2\u003e\n    \u003cp style=\"font-size: 15px; color: #444; margin: 0 0 20px 0; line-height: 1.8;\"\u003eThe GridBOSS sits at the service entrance between the utility meter and the home's load circuits — replacing what would otherwise require a collection of separate panels, transfer switches, and tap hardware. Utility power, hybrid inverter AC outputs, generator input, and smart load circuits all connect to the GridBOSS's internal 315A bus, which the device's relay logic and software manage according to grid status, battery state, and programmed priorities.\u003c\/p\u003e\n\n    \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eNormal Grid-Connected Operation:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eDuring normal grid operation, the GridBOSS passes utility power to all load circuits while simultaneously managing solar production from connected hybrid inverters — directing excess generation to charge batteries or export to the grid per the configured operating mode. All four smart ports remain active and fully powered, and the connected hybrid inverters operate in grid-interactive mode, synchronized to utility frequency and voltage.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eGrid Outage — Automatic Island \u0026amp; Microgrid Formation:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eUpon detecting grid loss, the GridBOSS opens its utility relay within ~25ms, isolating the home from the utility and preventing back-feed. Connected hybrid inverters receive the island command and switch to grid-forming mode, establishing a local 120\/240Vac microgrid from battery and solar resources. Smart load ports can be automatically de-energized in sequence based on battery state of charge thresholds — shedding non-essential loads first to maximize backup duration for critical circuits.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 0;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eGenerator Integration \u0026amp; Priority Management:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eWhen battery reserves reach a configured low threshold during an extended outage, the GridBOSS can signal an automatic start generator through its programmable driver outputs. Generator AC power enters through the dedicated 125A generator input port, is synchronized and managed by the device's relay logic, and is used to recharge batteries and supply loads — all within a single coordinated device that eliminates the need for a separate generator transfer switch or manual intervention.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- What's Included \/ Not Included Section --\u003e\n  \u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 20px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eWhat's Included \u0026amp; What's Not\u003c\/h2\u003e\n    \u003cdiv style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 16px;\"\u003e\n      \u003cdiv style=\"background-color: #f0f7f0; border-radius: 6px; padding: 24px; border-left: 4px solid #22c55e;\"\u003e\n        \u003cdiv style=\"font-weight: 700; color: #166534; font-size: 15px; margin-bottom: 14px;\"\u003e✅ Included in This Unit\u003c\/div\u003e\n        \u003cul style=\"margin: 0; padding-left: 18px; color: #444; font-size: 14px; line-height: 2;\"\u003e\n          \u0026gt;GridBOSS MID enclosure (NEMA 3R rated)\n          \u0026gt;Integrated relay logic \u0026amp; control board\n          \u0026gt;8-circuit energy monitoring hardware\n          \u0026gt;5 programmable output drivers\n          \u0026gt;Internal 315A bus assembly\n          \u0026gt;4 smart \/ AC-couple port bus connections\n          \u0026gt;Wi-Fi \/ monitoring interface\n          \u0026gt;Wall mounting hardware\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"background-color: #fef9f0; border-radius: 6px; padding: 24px; border-left: 4px solid #f59e0b;\"\u003e\n        \u003cdiv style=\"font-weight: 700; color: #92400e; font-size: 15px; margin-bottom: 14px;\"\u003e⚠️ Sold Separately (Not Included)\u003c\/div\u003e\n        \u003cul style=\"margin: 0; padding-left: 18px; color: #444; font-size: 14px; line-height: 2;\"\u003e\n          \u0026gt;Main service entrance breaker (200A Eaton CSR2200N recommended)\n          \u0026gt;Hybrid inverter input breakers (up to 3 × 90A)\n          \u0026gt;Generator input breaker (up to 125A)\n          \u0026gt;Smart port breakers (125A, 80A, 60A, 60A)\n          \u0026gt;Hybrid inverters \u0026amp; battery systems\n          \u0026gt;Generator\n          \u0026gt;Utility meter \u0026amp; meter socket\n        \u003c\/ul\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Technical Specifications Section --\u003e\n  \u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eTechnical Specifications\u003c\/h2\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eManufacturer\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eEG4 Electronics\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003ePart Number\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eEG4MID2P200AV3.1\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDevice Type\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eMicrogrid Interconnect Device (MID) | Service Entrance Rated | Intelligent Power Distribution\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eNominal AC Voltage\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e120\/240 Vac Split-Phase (L1 \/ L2 \/ N required)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eFrequency\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e60 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMaximum Current\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e200A (Backed-Up Loads) + 200A (Non-Backed-Up Loads)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eInternal Bus Rating\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e315A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eInterrupt Capacity\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e22 kAIC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eHybrid Inverter Ports\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eUp to 3 × 90A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eSmart \/ AC-Couple Ports\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e4 Ports — Port 1: 125A | Port 2: 80A | Port 3: 60A | Port 4: 60A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eGenerator Input\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eUp to 125A (30 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eTransfer Time (Grid Outage)\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e~25 ms\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eEnergy Monitoring Circuits\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e8 Circuits\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eProgrammable Output Drivers\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e5 Drivers\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eIdle Consumption\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e~55W\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eConnectivity\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eWi-Fi | EG4 Monitoring App (iOS \u0026amp; Android)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eEnclosure Rating\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNEMA 3R — Indoor or Outdoor\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eOperating Ambient Temperature\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e-40°F to 113°F (-40°C to 45°C)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e31.5\" × 19.7\" × 7.0\" (800 × 500 × 178 mm)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eWeight\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e55 lbs (25 kg)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eRecommended Main Breaker\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e200A Eaton CSR2200N (CSR25K) — Sold Separately\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eWarranty\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e10-Year Standard Warranty\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Certifications \u0026 Compliance Section --\u003e\n  \u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff; border-left: 4px solid #1e3a5f;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n    \u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.9;\"\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eSafety \/ Grid Standards:\u003c\/span\u003e UL 1741 | UL 67 | UL 869A | UL 916 | CSA C22.2 #29:2015 ED.6+U1\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eEMC:\u003c\/span\u003e FCC Part 15, Class B\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eService Entrance Rating:\u003c\/span\u003e 200A with 200A Eaton CSR2200N (CSR25K) main breaker — US installations only (Model EG4MID2P200AV3.1)\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eNEC Compliance:\u003c\/span\u003e NEC 2020 §706 (Energy Storage Systems) | §705 (Interconnected Electric Power Production Sources)\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eEnclosure:\u003c\/span\u003e NEMA 3R — Rainproof, Indoor or Outdoor\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eWarranty:\u003c\/span\u003e 10-Year Standard Warranty\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Documentation Section --\u003e\n  \u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 20px 0;\"\u003eDocumentation\u003c\/h2\u003e\n    \u003cdiv style=\"display: flex; gap: 16px; flex-wrap: wrap;\"\u003e\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/EG4_GridBOSS_EG4MID2P200AV3.1_Microgrid_Interconnect_Device.pdf?v=1782643775\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid #1e3a5f; border-radius: 6px; background-color: #ffffff; color: #1e3a5f; text-decoration: none;\"\u003e\n          \u003cspan style=\"margin-right: 8px;\"\u003e📄\u003c\/span\u003e\u003cb\u003eDatasheet (PDF)\u003c\/b\u003e\n        \u003c\/span\u003e\n      \u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Availability Banner --\u003e\n  \u003cdiv style=\"background-color: #1e3a5f; padding: 24px 40px; margin-top: 24px; border-radius: 6px; text-align: center;\"\u003e\n    \u003cp style=\"margin: 0; color: #ffffff; font-size: 16px;\"\u003e\n      \u003cspan style=\"font-weight: bold; color: #4ade80;\"\u003e● Available\u003c\/span\u003e\n      \u003cspan style=\"margin: 0 16px; color: #7aa3d4;\"\u003e|\u003c\/span\u003e\n      \u003cspan style=\"font-weight: 400;\"\u003eContact us for lead time and pricing\u003c\/span\u003e\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"EG4","offers":[{"title":"Default Title","offer_id":44119235887238,"sku":"PES-7639353819270-1","price":1925.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/EG4GridBOSSEG4MID2P200AV3.1MicrogridInterconnectDevice.jpg?v=1782643675","url":"https:\/\/www.portlandiaelectric.supply\/products\/eg4-gridboss-eg4mid2p200av3-1-microgrid-interconnect-device","provider":"Portlandia Electric Supply","version":"1.0","type":"link"}