{"product_id":"enphase-iq8x-microinverter-mc4-split-phase-iq8x-80-m-dom-us","title":"Enphase IQ8X Microinverter (MC4 Split-Phase) – IQ8X-80-M-DOM-US","description":"\u003c!-- Enphase IQ8X Microinverter IQ8X-80-M-DOM-US - Shopify Product Description --\u003e\n\u003cdiv style=\"font-family: 'Segoe UI', Arial, sans-serif; max-width: auto; margin: 0 auto; color: #333; line-height: 1.6;\"\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 35px 40px; border-radius: 8px 8px 0 0; text-align: center;\"\u003e\n\u003ch2 style=\"color: #ffffff; font-size: 28px; font-weight: bold; margin: 0 0 12px 0; letter-spacing: 0.5px;\"\u003eEnphase IQ8X Microinverter — IQ8X-80-M-DOM-US\u003c\/h2\u003e\n\u003cp style=\"color: #a8c4e0; font-size: 16px; margin: 0; font-weight: 400;\"\u003eModel IQ8X-80-M-DOM-US | 384 VA Peak Output | 240 Vac Split-Phase | 60 Hz | 320–540W PV Input | 43–60V MPPT | US Domestically Manufactured | Grid-Forming Technology | Sunlight Backup™ Capable | MC4 Connectors | IP67 \/ NEMA 6 | NEC 2014–2023 §690.12 Rapid Shutdown | 25-Year Warranty\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Stats Boxes - 4 Columns --\u003e\n\u003cdiv style=\"display: flex; justify-content: space-between; gap: 0; margin: 0; border: 2px solid #d0d0d0; border-top: none;\"\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e384 VA\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003ePeak Output Power\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e97.3%\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003ePeak Efficiency\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003eMade in USA\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eUS Domestic Manufacture\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; background-color: #ffffff;\"\u003e\n\u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e25 Yrs\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eManufacturer Warranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Product Overview Section --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 16px 0; line-height: 1.8;\"\u003eThe \u003cstrong\u003eEnphase IQ8X-80-M-DOM-US\u003c\/strong\u003e is the US domestically manufactured variant of Enphase's IQ8X Microinverter — sharing identical electrical specifications, certifications, and performance characteristics with the IQ8X-80-M-US while satisfying Buy American Act (BAA) and domestic content requirements applicable to federally funded projects, ITC domestic content bonus adders, and procurement programs that mandate US-manufactured equipment. The \"DOM\" designation in the part number indicates domestic manufacture at Enphase's US production facility — the same advanced grid-forming microinverter hardware and firmware in a domestically compliant supply chain.\u003c\/p\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.8;\"\u003eThe IQ8X-80-M-DOM-US delivers 384 VA peak output at 240 Vac split-phase (L-L, 180°) and performs per-module MPPT across a 43–60V operating range, supporting high-powered 80-half-cell, 88-half-cell, and 96-cell PV modules rated from 320W to 540W with MC4 input connectors. As part of Enphase's IQ8 series, it features the industry's first grid-forming microinverter architecture — enabling Sunlight Backup™ operation during daytime grid outages without battery storage when paired with an IQ System Controller 2, and supporting full home energy independence configurations with IQ Batteries. NEC 2014 through NEC 2023 §690.12 rapid shutdown compliance is built in with no additional hardware. Backed by Enphase's 25-year limited warranty with connected IQ Gateway.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- DOM-US vs Standard Model Section --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eDOM-US vs. Standard Model — What's Different\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 20px 0; line-height: 1.8;\"\u003eThe IQ8X-80-M-DOM-US and IQ8X-80-M-US are electrically and functionally identical in every specification. The only difference is country of manufacture and supply chain origin — relevant for specific procurement, incentive, and compliance scenarios.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #1e3a5f;\"\u003e\n\u003cth style=\"padding: 14px 16px; text-align: left; color: #ffffff; font-weight: 600; width: 33%;\"\u003eAttribute\u003c\/th\u003e\n\u003cth style=\"padding: 14px 16px; text-align: left; color: #ffffff; font-weight: 600; width: 33%;\"\u003eIQ8X-80-M-DOM-US\u003c\/th\u003e\n\u003cth style=\"padding: 14px 16px; text-align: left; color: #ffffff; font-weight: 600; width: 33%;\"\u003eIQ8X-80-M-US\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e\u003cstrong\u003eUnited States\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eInternational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eITC Domestic Content Bonus\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e\u003cstrong\u003eEligible\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNot Eligible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eBuy American Act (BAA) Compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e\u003cstrong\u003eCompliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNon-Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIdentical\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIdentical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCertifications \u0026amp; Listings\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIdentical\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIdentical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eWarranty Terms\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIdentical (25 Years)\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIdentical (25 Years)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eInstallation \u0026amp; Monitoring\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIdentical\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIdentical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"background-color: #eef3f9; border-left: 4px solid #1e3a5f; padding: 16px 20px; border-radius: 0 6px 6px 0; margin-top: 20px;\"\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #444; line-height: 1.7;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eITC Domestic Content Bonus Adder (IRA §48):\u003c\/span\u003e Under the Inflation Reduction Act, solar projects using US-manufactured components may qualify for a domestic content bonus adder of up to 10 percentage points on the Investment Tax Credit (ITC). Inverters are a qualifying component category. Projects using the IQ8X-80-M-DOM-US instead of the standard model may be eligible for this bonus — consult your tax advisor and review current IRS guidance for project-specific eligibility requirements and documentation standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Four System Configurations Section --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 20px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eFour System Configurations\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0 0 20px 0; line-height: 1.8;\"\u003eThe IQ8X's grid-forming capability enables four distinct deployment configurations using the same microinverter hardware — from standard grid-tied solar to full whole-home energy independence.\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(2, 1fr); gap: 16px;\"\u003e\n\u003cdiv style=\"background-color: #ffffff; border-radius: 6px; padding: 20px; border: 1px solid #ddd;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #1e3a5f; font-size: 15px; margin-bottom: 8px;\"\u003e① Solar Only\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #555; line-height: 1.7;\"\u003eStandard grid-tied operation. Each IQ8X converts module DC to 240 Vac AC and feeds home loads and grid. No IQ System Controller or battery required. No Enphase University certification required to commission.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff; border-radius: 6px; padding: 20px; border: 1px solid #ddd;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #1e3a5f; font-size: 15px; margin-bottom: 8px;\"\u003e② Sunlight Backup™ — Battery-Free Daytime Backup\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #555; line-height: 1.7;\"\u003eDuring a grid outage, IQ8X microinverters island and continue producing power from solar with no battery required. Requires IQ System Controller 2. Backup power available proportional to available sunlight — approximately 25% of array capacity supports stable essential loads.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff; border-radius: 6px; padding: 20px; border: 1px solid #ddd;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #1e3a5f; font-size: 15px; margin-bottom: 8px;\"\u003e③ Home Essentials Backup\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #555; line-height: 1.7;\"\u003eSolar plus one or more IQ Batteries backs up essential circuits — refrigerator, lighting, network, device charging — through outages including nights and cloudy periods. Requires IQ System Controller 2.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff; border-radius: 6px; padding: 20px; border: 1px solid #ddd;\"\u003e\n\u003cdiv style=\"font-weight: bold; color: #1e3a5f; font-size: 15px; margin-bottom: 8px;\"\u003e④ Full Energy Independence\u003c\/div\u003e\n\u003cdiv style=\"font-size: 14px; color: #555; line-height: 1.7;\"\u003eSolar plus larger IQ Battery capacity provides whole-home 24\/7 backup through extended outages. Requires IQ System Controller 2. Enphase University certification required to commission this configuration.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Key Benefits Section --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eGrid-Forming Architecture — Powers Your Home During Outages Without a Battery:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eUnlike conventional grid-following microinverters that shut off the instant the utility grid goes down — because they have no AC voltage reference to synchronize to — the IQ8X contains a purpose-built grid-forming chip that autonomously generates its own AC voltage and frequency reference from scratch. When the IQ System Controller 2 islands the home during an outage, the IQ8X microinverters collectively maintain a stable 240 Vac \/ 60 Hz microgrid for the home's protected loads, powered entirely by real-time solar production. This Sunlight Backup™ capability operates with no battery required — a meaningful, low-cost resilience upgrade for homeowners who experience frequent daytime grid interruptions and need essential circuit power during those events.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eOptimized for the Latest High-Voltage 80\/88\/96-Cell Modules:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe IQ8X's 79.5V maximum input voltage and 43–60V MPPT range are specifically engineered for the higher open-circuit voltages (Voc) produced by modern large-format module designs — including 80-half-cut cell, 88-half-cut cell, and 96-cell configurations that have become the dominant format in residential solar module production. These modules regularly produce Voc values that exceed the maximum input voltage tolerance of prior IQ7-series microinverters, making the IQ8X the correct and only Enphase microinverter platform for installations using current-generation 430W–540W large-format modules. The 14A maximum Isc rating also accommodates the higher short-circuit currents produced by modern high-efficiency cell designs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003ePer-Module MPPT — Zero Mismatch Loss Across Any Roof Configuration:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eEvery IQ8X-80-M-DOM-US performs independent MPPT at its individual module with no string current coupling to any other module in the system — enabling installations on complex multi-face rooftops where modules on east, west, south, and north faces can be mixed in any combination without any mismatch penalty. A shaded module on the east face produces whatever it can without affecting production on any other face. There is no string voltage calculation to verify, no tilt-angle-match constraint to manage, and no partial-shading production penalty to estimate — every module in the array operates at its own maximum power point at every moment of every day.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eNo Enforced DC\/AC Ratio — Maximum Module Pairing Flexibility:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eSolarEdge optimizer systems enforce string-level DC\/AC power ratio limits that restrict which module wattages can be paired with which inverter sizes. The IQ8X imposes no DC\/AC ratio constraint — any module with DC output between 320W and 540W can be paired directly, and module power tolerance up to +5% above nominal is also accommodated. This gives system designers complete freedom to specify the highest-wattage module available in any given project timeline without recalculating string design constraints or replacing inverter equipment — a significant advantage as module wattages continue to increase each product generation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 20px;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eBuilt-In Rapid Shutdown — NEC 2014 Through NEC 2023 Compliant:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eBecause the IQ8X performs DC\/AC conversion at the module, DC conductors on the rooftop are limited to module-level voltages (79.5V maximum Voc per module) with no long-run high-voltage DC string wiring traversing the roof surface. This inherently satisfies NEC §690.12 roof-surface rapid shutdown boundary requirements for both AC and DC conductors across all NEC code cycles from 2014 through 2023 — without any additional initiator devices, conductor-level shutdown modules, or separate rapid shutdown hardware. As jurisdictions adopt newer NEC cycles, IQ8X installations remain compliant with the updated code without any hardware modification or field retrofits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 0;\"\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eRemote Firmware Updates — Future Grid Requirement Compliance via IQ Gateway:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe IQ8X's software-defined architecture allows Enphase to push over-the-air firmware updates to every microinverter in the field via the IQ Gateway's internet connection — updating grid support parameters, reactive power curves, ride-through settings, and advanced grid functions to comply with new utility interconnection requirements as they are adopted, without any truck rolls, hardware replacements, or site visits. For installers and system owners, this means IQ8X systems installed today remain fully compliant with grid requirements adopted years from now — eliminating the risk of equipment obsolescence on evolving utility interconnection programs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Technical Specifications Section --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eEnphase Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIQ8X-80-M-DOM-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eUnited States (Domestic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eGrid-Forming Microinverter — Module-Level Power Electronics (MLPE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003ePeak Output Power\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e384 VA @ 240 Vac | 366 VA @ 208 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMaximum Continuous Output Power\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e380 VA @ 240 Vac | 360 VA @ 208 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eNominal AC Output Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e240 Vac — Split-Phase (L-L), 180° | Also Supports 208 Vac Single-Phase (Grid-Tied Only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eNominal AC Output Frequency\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDC Input Power Range\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e320 – 540 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMPPT Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e43 – 60 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDC Operating Range\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e25 – 79.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMaximum DC Input Voltage (Voc)\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e79.5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMaximum Input DC Short-Circuit Current (Isc)\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e16 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMaximum Module Isc\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMaximum Continuous Operating DC Current\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e10 Adc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e97.3% @ 240 Vac | 97.0% @ 208 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCEC Weighted Efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e96.5% (Both 240 Vac and 208 Vac)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDC\/AC Ratio\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNo Enforced Limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMax Units per 20 A (L-L) Branch Circuit\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e10 Units @ 240 Vac | 9 Units @ 208 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDC Input Connector\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eStäubli MC4 (Integrated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eEnphase PLC — Over Existing AC Branch Circuit Wiring to IQ Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMonitoring Platform\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eEnphase App (iOS \u0026amp; Android) via IQ Gateway — Real-Time Per-Module Visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eBackup Configurations Supported\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eSunlight Backup™ (No Battery) | Home Essentials Backup | Full Energy Independence — Requires IQ System Controller 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eNighttime Power Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e26 mW @ 240 Vac | 12 mW @ 208 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e-40°C to +65°C (-40°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e4% – 100% (Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eNatural Convection — No Moving Parts, No Fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIP67 | NEMA Type 6 | Class II Double-Insulated Corrosion-Resistant Polymeric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e212 mm × 175 mm × 30.2 mm (8.3\" × 6.9\" × 1.2\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e1.1 kg (2.43 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e25-Year Limited Warranty — Requires Internet-Connected IQ Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- Certifications \u0026 Compliance Section --\u003e\n\u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff; border-left: 4px solid #1e3a5f;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.9;\"\u003e\u003cspan style=\"font-weight: 600;\"\u003eGrid \/ Safety (US):\u003c\/span\u003e CA Rule 21 (UL 1741-SA) | IEEE 1547:2018 (UL 1741-SB) | UL 62109-1 (Class II Double-Insulated Safety)\u003cbr\u003e\u003cspan style=\"font-weight: 600;\"\u003eCanada:\u003c\/span\u003e CAN\/CSA-C22.2 No. 107.1-01 | C22.1-2018 Rule 64-218 Rapid Shutdown\u003cbr\u003e\u003cspan style=\"font-weight: 600;\"\u003eEMC:\u003c\/span\u003e FCC Part 15 Class B | ICES-0003 Class B\u003cbr\u003e\u003cspan style=\"font-weight: 600;\"\u003eRapid Shutdown:\u003c\/span\u003e UL Listed PV Rapid Shutdown Equipment — NEC 2014, 2017, 2020 \u0026amp; 2023 §690.12 Compliant (AC \u0026amp; DC Conductors) — No Additional Hardware Required\u003cbr\u003e\u003cspan style=\"font-weight: 600;\"\u003eProcurement:\u003c\/span\u003e Buy American Act (BAA) Compliant | ITC Domestic Content Bonus Adder (IRA §48) Eligible — Consult Tax Advisor for Project-Specific Eligibility\u003cbr\u003e\u003cspan style=\"font-weight: 600;\"\u003eEnclosure:\u003c\/span\u003e IP67 | NEMA Type 6 | Pollution Degree 3 | Approved for Wet Locations\u003cbr\u003e\u003cspan style=\"font-weight: 600;\"\u003eFirmware:\u003c\/span\u003e Remote Automatic Updates via IQ Gateway — Future Grid Requirement Compliance Without Hardware Changes\u003cbr\u003e\u003cspan style=\"font-weight: 600;\"\u003eWarranty:\u003c\/span\u003e 25-Year Limited Manufacturer Warranty — Requires Internet-Connected IQ Gateway\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Documentation Section --\u003e\n\u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n\u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 20px 0;\"\u003eDocumentation\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; gap: 16px; flex-wrap: wrap;\"\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/6763_321-0034_Data_Sheet.pdf?v=1782762095\" target=\"_blank\"\u003e \u003cspan style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid #1e3a5f; border-radius: 6px; background-color: #ffffff; color: #1e3a5f; text-decoration: none;\"\u003e \u003cspan style=\"margin-right: 8px;\"\u003e📄\u003c\/span\u003e\u003cb\u003eDatasheet (PDF)\u003c\/b\u003e \u003c\/span\u003e \u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Availability Banner --\u003e\n\u003cdiv style=\"background-color: #1e3a5f; padding: 24px 40px; margin-top: 24px; border-radius: 6px; text-align: center;\"\u003e\n\u003cp style=\"margin: 0; color: #ffffff; font-size: 16px;\"\u003e\u003cspan style=\"font-weight: bold; color: #4ade80;\"\u003e● Available\u003c\/span\u003e \u003cspan style=\"margin: 0 16px; color: #7aa3d4;\"\u003e|\u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003eContact us for lead time and pricing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Enphase","offers":[{"title":"Default Title","offer_id":44087814422662,"sku":"PES-SPS-SIV-07910","price":205.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/IQ8X-80-M-DOM-US_USSS.jpg?v=1781909625","url":"https:\/\/www.portlandiaelectric.supply\/products\/enphase-iq8x-microinverter-mc4-split-phase-iq8x-80-m-dom-us","provider":"Portlandia Electric Supply","version":"1.0","type":"link"}