{"product_id":"fortress-power-eforce-19-2-19-2kw-energy-storage-system-19-2kwh-capacity","title":"Fortress Power eForce 19.2 19.2kW Energy Storage System (19.2kWh Capacity)","description":"\u003c!-- Fortress Power eForce 19.2 - 400Ah\/19.2kWh 48V LFP Battery Kit - Shopify Product Description --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- Copy everything below into your Shopify product description editor --\u003e\n\u003cdiv style=\"font-family: 'Segoe UI', Arial, sans-serif; max-width: auto; margin: 0 auto; color: #333; line-height: 1.6;\"\u003e\n\n  \u003c!-- Dark Header Banner --\u003e\n  \u003cdiv style=\"background-color: #1e3a5f; padding: 35px 40px; border-radius: 8px 8px 0 0; text-align: center;\"\u003e\n    \u003ch2 style=\"color: #ffffff; font-size: 28px; font-weight: bold; margin: 0 0 12px 0; letter-spacing: 0.5px;\"\u003eFortress Power eForce 19.2 — Outdoor LFP Battery Storage Kit\u003c\/h2\u003e\n    \u003cp style=\"color: #a8c4e0; font-size: 16px; margin: 0; font-weight: 400;\"\u003eModel eForce 19.2 | 19.2 kWh | 400Ah | 48V | LFP | IP65 Outdoor Rated | Built-In Heater | Includes eWay Combiner, Cables \u0026amp; Floor Mount | 10-Year Warranty\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Stats Boxes - 4 Columns --\u003e\n  \u003cdiv style=\"display: flex; justify-content: space-between; gap: 0; margin: 0; border: 2px solid #d0d0d0; border-top: none;\"\u003e\n    \u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n      \u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e19.2 kWh\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eTotal Energy Capacity\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n      \u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e8,000\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eCycle Life @ 70% EOL\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; border-right: 2px solid #d0d0d0; background-color: #ffffff;\"\u003e\n      \u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003e14.4 kW\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eSurge Discharge (10s)\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex: 1; text-align: center; padding: 24px 16px; background-color: #ffffff;\"\u003e\n      \u003cdiv style=\"font-size: 28px; font-weight: bold; color: #1e3a5f; margin-bottom: 6px;\"\u003eIP65\u003c\/div\u003e\n      \u003cdiv style=\"font-size: 13px; color: #666; text-transform: uppercase; letter-spacing: 1px;\"\u003eOutdoor \/ All-Weather Rated\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Product Overview Section --\u003e\n  \u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eProduct Overview\u003c\/h2\u003e\n    \u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.8;\"\u003eThe \u003cstrong\u003eFortress Power eForce 19.2\u003c\/strong\u003e is a complete 19.2 kWh outdoor-rated lithium iron phosphate (LFP) energy storage kit comprising two stacked 9.6 kWh Tier-1 prismatic LFP battery modules — each with a built-in temperature-sensor-controlled heater — topped with the Fortress eWay integrated AC\/DC combiner and wireway, pre-assembled cables, and a floor-standing mount. Rated at 400Ah \/ 48V nominal with an IP65 ingress protection rating, the eForce 19.2 is engineered for all-weather outdoor installation, supporting operating temperatures from -4°F to 140°F (-20°C to 60°C) without derating. With 8,000 cycle life at 70% end-of-life capacity, a 250A maximum charge\/discharge current, 14.4 kW surge discharge capability, and native RS485 \/ Wi-Fi \/ CAN communication for closed-loop BMS integration with compatible inverters, the eForce 19.2 is purpose-built for whole-home backup, solar self-consumption, off-grid, and Virtual Power Plant (VPP) applications. The kit is compatible with the Fortress Power Envy 8kW, 10kW, and 12kW inverters, and the system is scalable to up to eight 19.2 kWh units in parallel for a total of 153.6 kWh.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Benefits Section --\u003e\n  \u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eKey Benefits\u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eIP65 Outdoor Rating + Built-In Temperature-Controlled Heater:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe eForce 19.2 is fully sealed to IP65 — protected against dust ingress and water jets from any direction — making it suitable for direct outdoor wall or floor installation in garages, carports, or exterior locations without a separate enclosure. Each battery module contains an integrated electric heater that activates automatically when cell temperature drops below the operational threshold, keeping the LFP cells within their optimal performance window down to -4°F (-20°C) and preventing cold-temperature capacity loss that affects standard outdoor batteries.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eeWay Integrated Combiner — All AC\/DC Connections in One Place:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe Fortress eWay wireway sits atop the stacked battery modules and serves as the system's central AC\/DC connection hub — integrating busbars, cable conduit ports, and a lockable, taggable power disconnect (eDisconnect) in a single assembly that eliminates the need for a separate DC combiner box or manual disconnect hardware. All inverter AC connections, battery DC bus connections, and communication wiring route through the eWay, significantly reducing installation time and simplifying field wiring for the installing technician.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003e8,000-Cycle Life — 20-Year Design Life:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe Tier-1 prismatic LFP cells inside the eForce 19.2 are rated for 8,000 full charge\/discharge cycles at 70% end-of-life capacity — equivalent to over 21 years of daily cycling. This cycle life guarantee is backed by a 10-year standard warranty, with upgrade options available to extend coverage to 30 years when the eForce is installed as a complete system with the Fortress Envy inverter and Guardian Gateway, making it one of the longest-warranted residential battery systems on the market.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003e250A Continuous + 14.4 kW Surge Discharge:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eA maximum continuous charge\/discharge current of 250A enables rapid charging from high-power solar arrays and fast discharge to support whole-home loads simultaneously, while a 14.4 kW surge discharge capability for 10 seconds handles the high inrush currents of large motor loads — central air conditioners, well pumps, electric water heaters — without triggering BMS protection cutoffs or dropping loads during startup.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 20px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eModular \u0026amp; Scalable — Up to 153.6 kWh Per System:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe eForce 19.2 is stackable and fully modular. Up to eight 19.2 kWh units can be connected in parallel on a single system, scaling total storage capacity from 19.2 kWh to 153.6 kWh — enabling the same base hardware to serve a small residential backup installation today and a whole-home or light commercial off-grid application as energy needs grow.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 0;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eClosed-Loop BMS with RS485, Wi-Fi \u0026amp; CAN Communication:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eNative RS485, Wi-Fi, and CAN communication interfaces enable the eForce 19.2 to establish a closed-loop BMS connection with compatible inverters — passing real-time cell voltage, state of charge, temperature, and charge\/discharge limits directly to the inverter's control firmware for fully coordinated, cell-level managed charging and discharging. This eliminates the voltage-only open-loop charging limitations of generic battery\/inverter pairings and maximizes both cycle life and usable capacity over the life of the system.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- How It Works Section --\u003e\n  \u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eHow It Works\u003c\/h2\u003e\n    \u003cp style=\"font-size: 15px; color: #444; margin: 0 0 20px 0; line-height: 1.8;\"\u003eThe eForce 19.2 operates as a 48V DC battery bank that connects to a compatible hybrid inverter (Fortress Envy 8kW, 10kW, or 12kW recommended) through the eWay combiner's integrated DC bus. The inverter manages all DC-to-AC conversion, battery charge regulation, grid interaction, and backup switching — while the eForce battery's integrated BMS communicates cell-level status data to the inverter continuously via the closed-loop communication link.\u003c\/p\u003e\n\n    \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eIntegrated BMS — Active Cell-Level Management:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eEach of the two 9.6 kWh battery modules within the eForce 19.2 contains an independent Battery Management System that monitors individual cell voltage, state of charge, temperature, and health in real time. The master BMS coordinates both modules as a unified 400Ah \/ 48V bank and communicates charge\/discharge current limits, state-of-charge percentage, and fault status to the inverter via CAN or RS485 — allowing the inverter to charge and discharge the battery at the exact current rate the cells can safely accept at that moment, rather than using fixed voltage setpoints.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 16px;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eBuilt-In Heater — Cold Weather Self-Protection:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eLFP cells experience significant capacity reduction and can sustain permanent damage if charged at sub-zero temperatures. The eForce 19.2's integrated temperature-controlled heater activates automatically when internal battery temperature approaches the cold threshold — warming the cells to their operational range before charge begins and maintaining thermal stability throughout cold-weather discharge events, without any user intervention or external thermostat required.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"margin-bottom: 0;\"\u003e\n      \u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"font-weight: bold; color: #1e3a5f;\"\u003eeWay Combiner — Simplified Field Wiring:\u003c\/span\u003e \u003cspan style=\"color: #444;\"\u003eThe eWay wireway provides the physical and electrical interface between the stacked battery modules and the installed inverter. The integrated busbar accepts the DC output from both battery modules and routes combined DC power to the inverter via pre-terminated cables included in the kit. AC wiring from the inverter and communication cables to the BMS also route through the eWay's conduit ports, keeping all high-current connections organized, strain-relieved, and enclosed — and providing a single lockable eDisconnect point that de-energizes the entire battery bank for safe maintenance.\u003c\/span\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- What's In The Kit Section --\u003e\n  \u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 20px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eWhat's In The Kit\u003c\/h2\u003e\n    \u003cdiv style=\"display: grid; grid-template-columns: 1fr 1fr 1fr 1fr; gap: 14px;\"\u003e\n      \u003cdiv style=\"background-color: #f5f5f5; border-radius: 6px; padding: 18px; text-align: center;\"\u003e\n        \u003cdiv style=\"font-size: 26px; margin-bottom: 8px;\"\u003e🔋\u003c\/div\u003e\n        \u003cdiv style=\"font-weight: 600; color: #1e3a5f; font-size: 14px; margin-bottom: 6px;\"\u003e2 × eForce 9.6 kWh Modules\u003c\/div\u003e\n        \u003cdiv style=\"font-size: 13px; color: #666;\"\u003eTier-1 prismatic LFP, 200Ah each, with integrated BMS \u0026amp; built-in heater\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"background-color: #f5f5f5; border-radius: 6px; padding: 18px; text-align: center;\"\u003e\n        \u003cdiv style=\"font-size: 26px; margin-bottom: 8px;\"\u003e⚡\u003c\/div\u003e\n        \u003cdiv style=\"font-weight: 600; color: #1e3a5f; font-size: 14px; margin-bottom: 6px;\"\u003eeWay Combiner (AC\/DC)\u003c\/div\u003e\n        \u003cdiv style=\"font-size: 13px; color: #666;\"\u003eIntegrated busbar, conduit ports, lockable eDisconnect — mounts on top of battery stack\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"background-color: #f5f5f5; border-radius: 6px; padding: 18px; text-align: center;\"\u003e\n        \u003cdiv style=\"font-size: 26px; margin-bottom: 8px;\"\u003e🔌\u003c\/div\u003e\n        \u003cdiv style=\"font-weight: 600; color: #1e3a5f; font-size: 14px; margin-bottom: 6px;\"\u003ePre-Terminated Cables\u003c\/div\u003e\n        \u003cdiv style=\"font-size: 13px; color: #666;\"\u003eDC battery interconnect \u0026amp; inverter connection cables included for fast, error-free installation\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv style=\"background-color: #f5f5f5; border-radius: 6px; padding: 18px; text-align: center;\"\u003e\n        \u003cdiv style=\"font-size: 26px; margin-bottom: 8px;\"\u003e🔩\u003c\/div\u003e\n        \u003cdiv style=\"font-weight: 600; color: #1e3a5f; font-size: 14px; margin-bottom: 6px;\"\u003eFloor-Standing Mount\u003c\/div\u003e\n        \u003cdiv style=\"font-size: 13px; color: #666;\"\u003eHeavy-duty floor mount bracket for stable freestanding installation indoors or outdoors\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Technical Specifications Section --\u003e\n  \u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 24px 0; border-bottom: 2px solid #1e3a5f; padding-bottom: 10px; display: inline-block;\"\u003eTechnical Specifications\u003c\/h2\u003e\n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; width: 45%; background-color: #eaeaea;\"\u003eManufacturer\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eFortress Power\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eModel\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eeForce 19.2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eBattery Chemistry\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eLithium Iron Phosphate (LFP) — Tier-1 Prismatic 15-Cell Modules\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eConfiguration\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e2 × 9.6 kWh Modules Stacked Vertically (2 × 200Ah)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eNominal Energy Capacity\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e19.2 kWh\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eNominal Capacity\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e400 Ah\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eNominal Voltage\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e48 VDC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eOperating Voltage Range\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e39V – 54V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eRe-Charge Voltage\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e46V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCut-Off Voltage\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e42V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eBulk \/ Absorption Charge Voltage\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e52.5V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMax Charge \/ Discharge Current\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e250A \/ 250A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eClosed-Loop Charge \/ Discharge\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e240A \/ 250A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eOpen-Loop Charge \/ Discharge\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e200A \/ 200A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eSurge Discharge Power (10s)\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e14,400 W (14.4 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMaximum Short-Circuit Current\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e3,000A (5ms)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCycle Life\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e8,000 Cycles @ 70% EOL Capacity\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDesign Life\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e20 Years\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCommunication Interfaces\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eRS485 | Wi-Fi | CAN\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eCompatible Inverters\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eFortress Power Envy 8kW | 10kW | 12kW (Closed-Loop)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMax Units in Parallel\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e8 Units (153.6 kWh Maximum System)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eIngress Protection\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eIP65 — Dust-Tight \u0026amp; Water-Jet Protected | Indoor or Outdoor\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eOperating Ambient Temperature\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e-4°F to 140°F (-20°C to 60°C) — Built-In Heater Active Below Threshold\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e24.4\" × 9.4\" × 53.1\" (620 × 240 × 1,351 mm)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eWeight\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e465 lbs (210.9 kg)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eMounting Options\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003eFloor-Standing (Included) | Wall-Hung (Separate Accessory) | Ground-Mount\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd style=\"padding: 14px 16px; font-weight: 600; color: #333; background-color: #eaeaea;\"\u003eWarranty\u003c\/td\u003e\n          \u003ctd style=\"padding: 14px 16px; color: #444; background-color: #ffffff;\"\u003e10-Year Standard | Upgradeable to 30 Years with Full Fortress Envy System\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Certifications \u0026 Compliance Section --\u003e\n  \u003cdiv style=\"padding: 32px 40px; margin-top: 24px; background-color: #ffffff; border-left: 4px solid #1e3a5f;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 16px 0;\"\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n    \u003cp style=\"font-size: 15px; color: #444; margin: 0; line-height: 1.9;\"\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eBattery Safety:\u003c\/span\u003e UL 1973 | UL 9540 | UL 9540A (Large-Scale Fire Testing) | UN38.3 (Transportation)\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eEMC \/ Grid:\u003c\/span\u003e IEEE 1547 | FCC (SDOC)\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eInverter Safety (Envy):\u003c\/span\u003e UL 1741\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eIngress Protection:\u003c\/span\u003e IP65 — Suitable for Outdoor Installation Without Additional Enclosure\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eNEC Compliance:\u003c\/span\u003e NEC 2020 §706 (Energy Storage Systems)\u003cbr\u003e\n      \u003cspan style=\"font-weight: 600;\"\u003eWarranty:\u003c\/span\u003e 10-Year Standard | Up to 8,000 Cycles @ 70% EOL\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Documentation Section --\u003e\n  \u003cdiv style=\"background-color: #f5f5f5; padding: 32px 40px; margin-top: 24px; border-radius: 6px;\"\u003e\n    \u003ch2 style=\"font-size: 20px; font-weight: 600; color: #1e3a5f; margin: 0 0 20px 0;\"\u003eDocumentation\u003c\/h2\u003e\n    \u003cdiv style=\"display: flex; gap: 16px; flex-wrap: wrap;\"\u003e\n      \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/Fortress_Power_eForce_19.2_Data_Sheet.pdf?v=1782645046\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\n        \u003cspan style=\"display: inline-flex; align-items: center; font-size: 15px; padding: 12px 24px; border: 2px solid #1e3a5f; border-radius: 6px; background-color: #ffffff; color: #1e3a5f; text-decoration: none;\"\u003e\n          \u003cspan style=\"margin-right: 8px;\"\u003e📄\u003c\/span\u003e\u003cb\u003eDatasheet (PDF)\u003c\/b\u003e\n        \u003c\/span\u003e\n      \u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Availability Banner --\u003e\n  \u003cdiv style=\"background-color: #1e3a5f; padding: 24px 40px; margin-top: 24px; border-radius: 6px; text-align: center;\"\u003e\n    \u003cp style=\"margin: 0; color: #ffffff; font-size: 16px;\"\u003e\n      \u003cspan style=\"font-weight: bold; color: #4ade80;\"\u003e● Available\u003c\/span\u003e\n      \u003cspan style=\"margin: 0 16px; color: #7aa3d4;\"\u003e|\u003c\/span\u003e\n      \u003cspan style=\"font-weight: 400;\"\u003eContact us for lead time and pricing\u003c\/span\u003e\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Fortress Power","offers":[{"title":"Default Title","offer_id":44119236575366,"sku":null,"price":11941.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/FortressPower_eForce19.2_400Ah19.2kWh48VLFPOutdoorRatedBattery.png?v=1782644810","url":"https:\/\/www.portlandiaelectric.supply\/products\/fortress-power-eforce-19-2-19-2kw-energy-storage-system-19-2kwh-capacity","provider":"Portlandia Electric Supply","version":"1.0","type":"link"}