{"product_id":"sungrow-200-kva-1500vdc-800vac-12-mppt-3-phase-pv-string-inverter-sg200hx-us","title":"Sungrow 200 KVA 1500VDC 800VAC 12 MPPT 3 Phase PV String Inverter - SG200HX-US","description":"\u003ch2\u003eSungrow 200 KVA 1500VDC 800VAC 12 MPPT 3 Phase PV String Inverter - SG200HX-US\u003c\/h2\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.portlandiaelectric.supply\/products\/sungrow-200-kva-1500vdc-800vac-12-mppt-3-phase-pv-string-inverter-sg200hx-us\" target=\"_self\" title=\"\"\u003eSungrow 200 KVA 1500VDC 800VAC 12 MPPT 3 Phase PV String Inverter - SG200HX-US\u003c\/a\u003e delivers high-performance energy conversion for utility-scale and large commercial solar projects. It offers exceptional efficiency, advanced protection features, and smooth grid integration. Built to endure demanding energy environments, this inverter ensures steady and optimized solar power output. This makes it a favorite choice in modern PV infrastructure.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote:\u003c\/em\u003e Per Sungrow’s datasheet, SG200HX-US is a 200 kVA, 600 Vac model (AC voltage range 528–660 V). Specs below reflect the official datasheet.\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eInput (DC)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV input voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. \/ Startup input voltage\u003c\/td\u003e\n\u003ctd\u003e500 V \/ 550 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal PV input voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPP voltage range\u003c\/td\u003e\n\u003ctd\u003e500–1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull power MPP range @ 40 °C\u003c\/td\u003e\n\u003ctd\u003e850–1300 V *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo. of independent MPPTs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings per MPPT\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV input current\u003c\/td\u003e\n\u003ctd\u003e40 A per MPPT (total 12×40 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. DC short-circuit current per MPPT\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eOutput (AC)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output power\u003c\/td\u003e\n\u003ctd\u003e200 kVA @ 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC output current\u003c\/td\u003e\n\u003ctd\u003e193 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC voltage\u003c\/td\u003e\n\u003ctd\u003e3\/PE, 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage range\u003c\/td\u003e\n\u003ctd\u003e528–660 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal grid frequency \/ range\u003c\/td\u003e\n\u003ctd\u003e60 Hz \/ 55–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 3% (at nominal power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC current injection\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.5% In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor (nominal \/ adjustable)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.99 \/ 0.8 leading – 0.8 lagging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed-in phases \/ Connection phases\u003c\/td\u003e\n\u003ctd\u003e3 \/ 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eEfficiency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. efficiency \/ CEC efficiency\u003c\/td\u003e\n\u003ctd\u003e98.8% \/ 98.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eProtection \u0026amp; Safety\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC reverse connection \/ AC short circuit \/ Leakage current \/ Grid monitoring \/ Ground fault\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes \/ Yes \/ Yes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC switch \/ AC switch\u003c\/td\u003e\n\u003ctd\u003eYes \/ No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV string current monitoring \/ Q at night\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnti-PID \u0026amp; PID recovery\u003c\/td\u003e\n\u003ctd\u003eOptional (MVS3200-US \/ MVS4480-US)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd\u003eDC Type II \/ AC Type II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eGeneral Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e1165 × 870 × 361 mm (45.9 × 34.3 × 14.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e≤122 kg (≤269 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation \/ Enclosure\u003c\/td\u003e\n\u003ctd\u003eTransformerless \/ IP66 (NEMA 4X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNight power consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating ambient temperature\u003c\/td\u003e\n\u003ctd\u003e−30 to 60 °C (−22 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e0%–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eSmart forced air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating altitude\u003c\/td\u003e\n\u003ctd\u003e4000 m (\u0026gt;3000 m derating) \/ 13,123 ft (\u0026gt;9843 ft derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay \/ Communication\u003c\/td\u003e\n\u003ctd\u003eLED, Bluetooth+APP \/ RS485, SunSpec, Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC \/ AC connections\u003c\/td\u003e\n\u003ctd\u003eMC4 (Max. #10 AWG, optional #8) \/ OT\/DT terminal (Max. 750 kcmil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eUL 1741, UL 62109-1, CSA C22.2 No.107.1-16, IEEE 1547-2018, IEEE 1547.1-2020, UL 1741 SA\/SB, California Rule 21, FCC Part 15 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid support functions\u003c\/td\u003e\n\u003ctd\u003eQ at night, LVRT\/HVRT, active \u0026amp; reactive power control, power ramp rate, Q-U control, P-f control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003csmall\u003e* Full-power MPP range depends on temperature; see datasheet curve.\u003c\/small\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eHigh Efficiency and Optimized Power Generation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe unit is designed to maximize energy harvest even in variable weather or partial shading. With 12 independent MPPTs, it operates each string at ideal capacity. This reduces mismatch losses and improves yield. Its advanced MPPT tech reacts quickly to environmental changes, maintaining high energy output.\u003c\/p\u003e\n\u003ch2\u003eDurable Construction for Demanding Conditions\u003c\/h2\u003e\n\u003cp\u003eEngineered for long-term durability, this inverter handles tough outdoor conditions. It resists high temperatures, dust, and moisture effectively. With intelligent thermal design, heat dissipates efficiently. That allows continuous operation under extreme temperatures without performance loss or damage.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003eSungrow 200 KVA 1500VDC 800VAC 12 MPPT 3 Phase PV String Inverter - SG200HX-US\u003c\/strong\u003e Smart Monitoring and Intelligent Operation\u003c\/h2\u003e\n\u003cp\u003eThis model has a built-in smart monitoring system for easy tracking. Operators can detect faults and make decisions based on real-time data. Remote monitoring makes maintenance simpler and cheaper. Diagnostics work to prevent downtime, ensuring consistent power generation throughout its lifecycle.\u003c\/p\u003e\n\u003ch2\u003eEnhanced Safety Features\u003c\/h2\u003e\n\u003cp\u003eSafety is key in large-scale solar projects. This \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/Power_inverter\" target=\"_blank\" title=\"\" rel=\"noopener\"\u003einverter\u003c\/a\u003e offers arc-fault detection, ground fault monitoring, and rapid shutdown. Automatic fault isolation lowers risks but maintains function. Such safeguards assure users of reliable operation during all project phases.\u003c\/p\u003e\n\u003ch2\u003eGrid Support and Compliance\u003c\/h2\u003e\n\u003cp\u003eThe inverter complies with advanced grid support standards. It provides dynamic grid control, reactive power compensation, and low-voltage ride through capability. These features promote grid stability and improve energy delivery. Whether in utility or commercial fields, it fits modern grid infrastructure.\u003c\/p\u003e\n\u003ch2\u003eFlexible Design and Easy Installation\u003c\/h2\u003e\n\u003cp\u003eCompact and modular, it simplifies installation workflows. Lightweight and pre-wired options enable quick setup, saving project time. Its wide voltage support and flexible mounting suit many scenarios. Installers benefit from less labor, lower cabling, and easier commissioning.\u003c\/p\u003e\n\u003ch2\u003eSustainable and Cost-Efficient Performance\u003c\/h2\u003e\n\u003cp\u003eBy delivering high efficiency and reliability, this inverter helps projects speed ROI and lower operating costs. Its strong performance enhances sustainability by optimizing solar use. Intelligent engineering minimizes energy loss, making it cost-effective and eco-friendly.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the \u003cstrong\u003eSungrow 200 KVA 1500VDC 800VAC 12 MPPT 3 Phase PV String Inverter - SG200HX-US\u003c\/strong\u003e for Large-Scale Solar Projects\u003c\/h2\u003e\n\u003cp\u003eReliability, efficiency, and flexibility matter in demanding PV environments. This inverter has all these qualities. From monitoring to thermal stability and grid support, it boosts solar system output. It empowers developers, utilities, and businesses to meet long-term energy goals with optimized power conversion.\u003c\/p\u003e","brand":"Sungrow","offers":[{"title":"Default Title","offer_id":42500732190854,"sku":"PES-SPS-SIV-0722","price":22814.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/5188\/6982\/files\/Sungrow-SG350HX-US_frankensolar__56667.1722271548.jpg?v=1760382223","url":"https:\/\/www.portlandiaelectric.supply\/products\/sungrow-200-kva-1500vdc-800vac-12-mppt-3-phase-pv-string-inverter-sg200hx-us","provider":"Portlandia Electric Supply","version":"1.0","type":"link"}