The ATESS US standard 480V 500KVA isolation transformer is engineered to deliver exceptional electrical safety, stable power output, and long-term reliability for large commercial and industrial applications. Built with robust construction and advanced insulating technology, this transformer ensures clean, consistent power distribution where precision and safety matter. The ATESS US standard 480V 500KVA isolation transformer – Isolation Transformer 500-US-480 offers a dependable solution for operations needing maximum protection against voltage fluctuations, electrical disturbances, and harsh grid conditions.
Whether your facility demands enhanced electrical isolation, noise reduction, or a stable voltage environment for sensitive gear, this transformer is a trusted choice. Its 500KVA rating suits heavy loads, EV charging infrastructure, renewable systems, microgrids, and mission-critical industrial machines.
The ATESS 500kVA PCS isolation transformer is the matched medium-voltage interface for ATESS high-power storage—required with PCS500 and often used with PCS630—to provide galvanic isolation, neutral formation, and harmonic mitigation for robust C&I microgrids. [ATESS datasheet / dealer]
Designed for PCS integration, the ATESS 500kVA PCS isolation transformer operates at 400/400 V with a Dyn11 vector group, low losses (≈950 W no-load; 7.1 kW load @75 °C), and AF forced-air cooling in an IP00 indoor package. It forms a neutral (N-line) and reduces 3rd-harmonic components for cleaner power. [ATESS datasheet / dealer]
| Rated capacity | 500 kVA |
|---|---|
| Primary / secondary voltage | 400 V / 400 V |
| Primary / secondary current | ≈ 721.6 A / 721.6 A |
| Frequency | 50/60 Hz |
| Vector group | Dyn11 |
| No-load loss | ≈ 950 W |
| Load loss | ≈ 7.1 kW @ 75 °C |
| Insulation class | H |
| Protection | IP00 (indoor) |
| Cooling | AF (forced air) |
| Dimensions (W×H×D) | 1100 × 1700 × 1000 mm (≈ 43.31″ × 66.93″ × 39.37″) |
| Weight | ≈ 1500 kg (≈ 3307 lb) |
| Compatibility | For PCS500 (required); also applied with PCS630. PCS100/250 have built-in transformers. [ATESS US-480 datasheet / dealer] |
Choose the ATESS 500kVA PCS isolation transformer to complete your PCS500/PCS630 build with safe galvanic isolation, neutral formation, and low-loss performance verified by official ATESS specs.
The ATESS US standard 480V 500KVA isolation transformer performs under continuous load with balanced, safe power supply. It minimizes disruptions from harmonic distortion and electrical interference. Built durable, it withstands challenging environments for smooth operation year after year.
This model extends equipment life by reducing noise and enhancing voltage stability. Its isolated windings protect sensitive systems from spikes, surges, and transients. It is a smart investment for advanced electrical infrastructure.
This transformer is designed for high efficiency, ensuring minimal transmission power loss. Its electrical design lowers heat generation and boosts energy performance for high-demand, continuous applications.
Electrical isolation is central to the ATESS US standard 480V 500KVA isolation transformer, providing protection for connected equipment. Separating primary and secondary circuits prevents disturbances, improving safety and stability.
Its rugged design ensures reliable function in harsh environments. Installed indoors or outdoors, it consistently delivers stable power output.
The transformer cuts electrical noise significantly, ensuring smooth operation for sensitive equipment such as servers, automation units, EV chargers, and power electronics.
With a steady 480V output, the Isolation Transformer 500-US-480 reduces voltage fluctuations, letting equipment run efficiently without damage risk.
Large-scale EV stations need stable, noise-free power. This transformer supports high-capacity charging systems with clean output and no interference.
Solar, wind, and hybrid systems rely on transformers for grid stability. The ATESS US standard 480V 500KVA isolation transformer integrates seamlessly with energy solutions, providing grid isolation and surge protection.
Sensitive IT environments require steady power. This transformer reduces harmonics and supplies a safe, isolated power source for servers and network gear.
High-load machines run efficiently with clean, regulated power. This transformer supports motors, drives, and automation with reliable voltage accuracy.
From hurricanes to blackouts, reliable solar power ensures you're able to keep your home & family safe no matter what comes your way.
Making one-click solar solutions simple since 2018. Whether you’re powering a cabin, charging devices, or backing up your home.
Say goodbye to reliance on the energy companies. Enjoy the same freedom that 50,000+ customers have with their own solar power system.
$150 Value - Free Offer (Limited Time Only!) No Strings Attached. Totally Free. Takes Less than 2 Minutes.