Standby Generator Load Reference Chart — kW Sizing by Appliance

PES Supply, a PES Global Group Company
· 8 min read Reviewed by PES Supply editorial team
Whole Home Load Reference Continuous Watts by Circuit NEC 220 PES Distributor Chart

Table of Contents

    Generator Load Reference Chart — Whole-Home Watts by Circuit

    The reference table PES account reps use to size Generac, Cummins, Briggs & Stratton, and Kohler standby generators. Continuous watts and motor-start surge for every common residential and light-commercial load, plus the standard kW ladder and the transfer-switch, fuel-line, and pad-size decisions that follow from it.

    Whole-home load reference chart showing continuous watts by HVAC, kitchen, laundry, EV, water, and general circuits
    NEC 220
    Sizing basis
    4 brands
    Generac, Cummins, Briggs, Kohler
    8–200 kW
    Output range
    Instant
    Result — no submit required

    This page is the reference our account reps and installers turn to when a spec has to be defended in front of a homeowner or a general contractor: continuous watts by circuit, motor-start surge on the biggest inductive loads, the standard kW ladder that Generac, Cummins, Briggs & Stratton, and Kohler actually manufacture, and the transfer-switch, fuel-line, and pad-size decisions that follow. If you want the interactive version that lets you enter your job and get a recommended kW plus brand options in one screen, use the contractor portal generator sizing calculator — free with contractor account registration.

    Need the interactive version?

    Open the Contractor Portal Generator Sizing Calculator →

    Free with contractor account. Sign up here.

    Continuous Watts by Household Load (Reference Table)

    These are the numbers our account reps sum when a contractor calls with a new residential job. Continuous watts is what the appliance draws while running; motor-start surge is the extra draw for the first few seconds when an inductive load (an AC compressor, a well pump, a large refrigerator) energizes. The starting watts number is what your standby generator has to swallow in that instant. Add continuous watts across every appliance that could be running simultaneously, then add the single largest motor-start surge on top — that is the peak load.

    Load Continuous Watts (Running) Motor-Start Surge (Additional) Category
    Central AC — 2 ton 2,500 4,500 HVAC
    Central AC — 3 ton 3,600 6,000 HVAC
    Central AC — 4 ton 4,800 7,500 HVAC
    Central AC — 5 ton 6,000 9,000 HVAC
    Heat pump — 3 ton (with resistive strip) 7,600 6,000 HVAC
    Furnace blower / air handler 800 1,200 HVAC
    Electric water heater — 50 gal (4,500W element) 4,500 Water
    Electric water heater — 80 gal (5,500W element) 5,500 Water
    Well pump — ½ hp 1,000 2,000 Water
    Well pump — 1 hp 1,500 3,000 Water
    Well pump — 2 hp 2,400 4,800 Water
    Sump pump 1,050 2,200 Water
    Electric range — 4 burners + oven 5,000 Kitchen
    Electric range — 2 burners + oven 3,500 Kitchen
    Refrigerator (standard) 700 1,400 Kitchen
    Chest freezer 500 1,000 Kitchen
    Microwave (1,000W-class) 1,500 Kitchen
    Dishwasher (with heater) 1,500 Kitchen
    Electric dryer 5,500 Laundry
    Gas dryer (fan + igniter) 700 Laundry
    Clothes washer 1,150 2,300 Laundry
    EV charger — Level 2, 30 A 7,200 EV
    EV charger — Level 2, 40 A 9,600 EV
    EV charger — Level 2, 48 A 11,500 EV
    Hot tub / spa (240 V, 4 kW heater) 4,000 Comfort
    Whole-home lighting (LED) 400 General
    Whole-home lighting (mixed) 1,200 General
    Electronics + receptacles baseline 1,500 General
    Garage door opener 400 800 General
    Central vacuum 1,400 2,800 General

    How the Sizing Math Works

    The sizing math sums every continuous load — lights, receptacles, refrigeration, EV charging, water heater, electric range, electric dryer — into a single continuous watts figure. Then take the single largest inductive load (the biggest AC compressor or well pump) and add its motor-start surge on top. That combined peak is what the generator has to swallow the instant that compressor kicks in on a warm evening. That peak is then de-rated for fuel: natural gas loses about 10% of rated capacity versus liquid propane, so the required kW is scaled up 1.10× on NG. Finally, the result is rounded up to the next standard kW size on the 8–200 kW ladder that at least one of the four major brands stocks. The interactive calculator on the PES contractor portal runs this math for you and cross-references the sized kW against real Generac, Cummins, Briggs & Stratton, and Kohler product families.

    Worked example — 3,800 sq ft mixed-fuel home in Kentucky

    • Continuous baseline: 8,000 W (lights, fridge, receptacles).
    • 3-ton AC compressor: 3,600 W run, plus 1,600 W of start surge above run.
    • 1 hp well pump: 1,500 W run.
    • Electric range: 3,500 W (in use during outage).
    • Electric dryer: 5,500 W (assume in use).
    • Electric water heater: 4,500 W.
    • EV charger: 0 (customer confirmed unplugs during outage).
    • Continuous = 26,600 W. Peak with 3-ton start surge = 28,200 W. NG derate ×1.10 = 31,020 W ≈ 31.0 kW → rounded up to 36 kW liquid-cooled (Generac Protector RG03616 or Cummins C40).

    The Standard kW Ladder

    Standby generators are not made in every kW size. They come in a fixed ladder because that is how the OEMs manufacture engine and alternator combinations. The calculator rounds up to the next size on this ladder:

    kW Rung Class Typical Brands at This Size
    8 kW Air-cooled residential (entry) Generac Guardian, Briggs residential
    10 kW Air-cooled residential Generac 10 kW, Briggs 10 kW
    12 kW Air-cooled residential Generac 7175 (12 kW)
    14 kW Air-cooled residential Kohler 14RESA, Generac 14 kW
    16 kW Air-cooled residential Generac 16 kW
    20 kW Air-cooled residential Kohler 20RESA, Generac 20 kW, Briggs 20 kW
    22 kW Air-cooled residential (volume seller) Generac 7043, Cummins QC22, Briggs 22 kW
    24 kW Air-cooled residential Kohler 24RCL, Generac 24 kW
    26 kW Air-cooled residential (top of class) Generac 7291, Kohler 26RESV, Briggs 26 kW
    30 kW Liquid-cooled commercial (entry) Generac Protector RG03015, Kohler 30REZG, Briggs Fortress 30, Cummins C30
    36 kW Liquid-cooled Generac Protector RG03616, Cummins C40
    40 kW Liquid-cooled Cummins C40, Briggs Fortress 40
    45 kW Liquid-cooled Briggs Fortress 45, Kohler 48REZG
    48 kW Liquid-cooled Generac Protector RG04854, Kohler 48REZG
    50 kW Liquid-cooled Cummins C50
    60 kW Light commercial Generac SG060, Kohler 60REZG, Briggs Fortress 60, Cummins C60
    80 kW Commercial Kohler 80REOZJ, Cummins C80, Generac Industrial 80
    100 kW Commercial Kohler 100REOZK, Cummins C100, Generac Industrial 100
    125 kW Commercial Kohler 125REOZK, Cummins C125, Briggs Fortress 125
    150 kW Commercial/industrial Kohler 150REOZK, Generac Industrial 150
    200 kW Industrial Cummins C200 D6, Kohler 200REOZK

    How to Use the Result

    The recommended kW is the floor of what will run the site through a worst-case outage evening — the moment everything cycles on together. Two adjustments contractors typically make on top of the calculator:

    Add 10-15% headroom for future load growth

    If the customer might add an EV charger in year 2, a hot tub in year 3, or a second AC compressor when the addition is built, add 15% before rounding to the next kW. That usually moves a borderline 22 kW spec to a 26 kW, or a 48 kW commercial spec to a 60 kW.

    Down-size if intelligent load management is on the plans

    Generac Smart Management Modules (SMM) or equivalent load-shed relays let a 22 kW cover a house that raw math says needs 26 kW — the AC and the dryer can't both run at once. If SMM is in the spec, subtract the smaller of the two loads before sizing.

    Confirm the ATS amperage matches the service panel

    A 200A residential service panel needs a 200A service-entrance ATS for whole-home coverage. Don't spec a 100A ATS for a whole-home config — either upsize the ATS or move to load-shed with a smaller ATS. The two options price differently.

    Verify NG meter capacity before finalizing

    Utility gas meters at older homes are often 250 CFH — enough for a 14–16 kW generator but not a 22–26 kW under full load. Confirm meter capacity with the utility before locking the model number. Meter upsize is a permit and a utility appointment, not a same-week job.

    Quote the Job at Contractor Pricing

    Once the recommended kW is set, the fastest path to a real quote is to register for a contractor account. Tier-1 accounts see distributor pricing on every unit and OEM part on the site, get a named account rep for pallet buys and single-project bundles, and unlock the interactive generator sizing calculator plus voltage-drop, wire-sizing, and freight calculators on the contractor portal.

    Open a contractor account with PES Supply

    Get pallet-quantity pricing, tier discounts, and drop-ship freight on Generac, Cummins, Briggs & Stratton, and Kohler standby generators — plus access to the interactive sizing, voltage-drop, wire-sizing, and freight calculators on the PES contractor portal.

    Register for contractor pricing →

    Registered contractors — access the interactive calculators on the PES contractor portal

    Need Help Sizing This?

    Our team can help you calculate loads, select the right equipment, and source everything from one PO.

    📞 (502) 790-0600

    Email Our Team
    Solar Panels Generators Batteries / ESS EV Chargers Circuit Breakers Charge Controllers

    One PO. One Invoice. Every Trade Covered.

    PES Supply is the distribution arm of PES Global Group — 50,000+ SKUs from 169 authorized brands, LTL freight shipping from Louisville, KY.

    Get a Quote
    Share: X f in @

    Related Articles

    Kohler Standby Generator Lineup RESA REZG REOZK 14 to 150 kW PES Distributor Chart

    Kohler Standby Generator Authorized Distributor — Contrac...

    Aug 31, 2026
    Briggs and Stratton Standby Generator Lineup Fortress Residential 10 to 125 kW PES Distributor Chart

    Briggs & Stratton Standby Generator Authorized Distributo...

    Aug 31, 2026
    Cummins Standby Generator Lineup Quiet Connect C Series 13 to 200 kW PES Distributor Chart

    Cummins Standby Generator Authorized Distributor — Contra...

    Aug 31, 2026
    Generac Standby Generator Lineup 7 5 to 150 kW PES Distributor Chart

    Generac Standby Generator Authorized Distributor — Contra...

    Aug 31, 2026
    Standby Generator Brand Comparison Generac Cummins Briggs Kohler PES Distributor Chart

    Standby Generator Distributor — Generac, Cummins, Briggs ...

    Aug 31, 2026
    Generator Transfer Switch Types: Manual vs. Automatic (ATS) Guide

    Generator Transfer Switch Types: Manual vs. Automatic (AT...

    Jul 31, 2026
    Standby Generator Sizing Calculator: How to Choose the Right kW

    Standby Generator Sizing Calculator: How to Choose the Ri...

    Jul 31, 2026
    Generac Extended Warranty Guide: 10-Year Coverage, Cost & Registration

    Generac Extended Warranty Guide: 10-Year Coverage, Cost &...

    Jul 23, 2026
    Transfer Switch Sizing Chart: Match Amps to Your Generator & Panel

    Transfer Switch Sizing Chart: Match Amps to Your Generato...

    Jul 23, 2026
    Generator Fuel Consumption Chart: Propane, Natural Gas & Diesel by kW

    Generator Fuel Consumption Chart: Propane, Natural Gas & ...

    Jul 22, 2026
    Safety First: OSHA and NFPA Requirements for Solar Installation Crews

    Safety First: OSHA and NFPA Requirements for Solar Instal...

    Apr 15, 2026
    Backup generators in real-world settings: home standby, commercial, and portable units.

    Backup Generators: A Comprehensive Guide to Sizing, Types...

    Oct 31, 2025
    EG4 solar energy products display, including solar panels, inverters, batteries, and control units.

    EG4 Solar Products: Leading the Charge in Energy Solution...

    Mar 24, 2025
    Champion portable generators outdoors near RV and buildings, Portlandia Electric Supply ad

    Power Your Life with Champion Portable Generators: Electr...

    Mar 10, 2025
    Home Generator Solutions: Finding the Best Backup Power for Your Needs

    Home Generator Solutions: Finding the Best Backup Power f...

    Feb 20, 2025
    Reliable RV Generators – Top Cummins Inverter Options for Camping & Travel

    Discover the Best RV Generators: Expert Reviews and Insig...

    Feb 05, 2025
    2024 Generator Market Update: Standby Power Demand Surges with Grid Instability

    2024 Generator Market Update: Standby Power Demand Surges...

    Oct 15, 2024

    Get Price Drops & Product Releases

    Weekly digest for installers and project managers — price drops, new stock, NEC code updates.

    PES Supply, a PES Global Group Company