Quick Mount PV Brand Guide: QBase, Flashing Systems, and Waterproof Roof Attachments

PES Supply, a PES Global Group Company
· 15 min read PES Engineering Desk — reviewed by a licensed master electrician
Quick Mount PV roof flashing and mounting foot on shingles — PES Supply brand guide

Table of Contents

    Quick Mount PV Brand Guide: QBase, Flashing Systems, and Waterproof Roof Attachments

    QBase composition, tile, and low-slope mounts, Classic Comp retrofit attachments, the QBlock elevated seal, structural ratings, and how Quick Mount compares to IronRidge and Unirac flashings.

    QBase Mount System

    Quick Mount PV does one thing and has done it since 2006: roof attachments that don't leak. While the full-line racking companies split their engineering attention across rails, clamps, ground mounts, and carports, Quick Mount put two decades into the three square feet where the array meets the weather. The result is the attachment system our installer customers request by name for composition shingle and tile work — and the flashing that, in our warranty records, has the lowest leak-callback rate of anything we sell. This guide covers the QBase family, the seal technology, the structural math, and the honest comparison against IronRidge and Unirac. For the full-rack context, pair this with the IronRidge brand guide and our pitched-roof mounting guide.

    3,031 lbs
    Tested pullout, QBase Comp Mount in Doug fir
    25 yr
    Structural warranty (5-yr finish)
    2006
    Year Quick Mount PV was founded
    FL & LA
    Florida and Los Angeles approvals on QBase

    1. Company Overview

    Quick Mount PV was founded in 2006 in northern California by roofing-industry veterans who looked at early solar attachments — essentially standoffs bedded in sealant — and saw the roofing failures coming years before they arrived. The company's founding insight is that a roof penetration is a roofing problem first and a structural problem second, and that the solar industry was solving the wrong one. Every Quick Mount product treats the flashing as the primary component and the mount as the thing attached to it, which is exactly backwards from how most racking companies design.

    That roofing-first DNA is why the brand earns loyalty from the installers who own the long-term leak liability. I've stood on a roof in Salem with a roofer-turned-solar-installer who pulled a fifteen-year-old comp mount during a re-roof, cut the flashing open, and showed me the still-elastic seal around the post — "this is why I don't use anything else." We stock Quick Mount in depth precisely because of customers like him; browse the range in our Quick Mount collection and the broader racking and mounting inventory.

    2. Product Lines

    QBase Composition Mount (QMNC-A-12)

    The QBase Comp Mount is the flagship: a 12" × 12" spun-aluminum cone flashing — seamless, because seams leak — with a 3.25" cast post rising from the center. The cone sheds water exactly like the plumbing vent flashings roofers have trusted for a century, because that's the design lineage. Tested pullout in Douglas fir runs 3,031 lbs, and the system carries approvals for Florida's high-velocity hurricane requirements and the City of Los Angeles — two of the strictest review regimes in the country. Two or four lag screws depending on substrate and load; new construction and re-roof friendly since the flashing integrates with the shingle courses like any other roof penetration.

    Classic Comp Mount (Retrofit)

    The Classic Comp is the retrofit specialist for existing shingle roofs: a single-bolt install with the QBlock elevated seal, designed to slide into an existing shingle course without the full flashing replacement the new-construction QBase invites. When we're quoting an array on a ten-year-old roof that isn't being replaced, this is the attachment. The elevated seal keeps the water path below the seal plane even if the sealant ages — the same roofing-first logic as the cone flashings.

    QBase Universal Tile Mount

    Tile roofs punish improvised attachments, and the Universal Tile Mount is Quick Mount's answer: a tile-replacement flashing with a cast-aluminum base that transfers the mount load to the structure below, so the tile carries nothing. It covers concrete and clay tile in the common profiles. The labor reality of tile work stands — it's slower than comp shingle no matter whose hardware you use — but the leak risk drops to composition-roof levels when the tile never bears the mount.

    QBase Low Slope Mount

    For flat and low-slope membranes — TPO, PVC, EPDM, built-up asphalt — the Low Slope Mount anchors to wood, concrete, or steel substrates with included 3" lag bolts and integrates with the membrane per the roofer's detailing. Penetrating a membrane roof is a decision to make deliberately; compare against ballasted approaches in our flat-roof ballasted vs penetrating guide before committing.

    Model Category Key Specs Application
    QBase Composition Mount (QMNC-A-12) Roof attachment 12" × 12" cone flashing, 3.25" post, 3,031 lbs pullout Composition shingle, new construction / re-roof
    QBase Low Slope Mount Low-slope attachment Wood/concrete/steel substrate, 3" lag bolts included TPO, PVC, EPDM, built-up asphalt flat roofs
    QBase Universal Tile Mount Tile roof attachment Tile replacement flashing, cast aluminum base Concrete and clay tile roofs
    Classic Comp Mount Retrofit attachment QBlock elevated seal, single-bolt install Existing composition shingle roofs
    QBase Post (various heights) Standoff post 8 heights from 3.25" to 17.5", A360.1 cast aluminum Custom height requirements across QBase systems

    3. The QBlock Seal: Why It Works

    Most solar attachment seals sit at the water plane — the surface where water flows. The QBlock seal sits above it. The mount's post rises through a raised collar, and the seal lives at the top of that collar, elevated above the flashing's drainage surface. Water flowing down the roof would have to climb uphill and over the collar to reach the penetration, which is not what water does. Even if the sealant compound degrades in year eighteen, the geometry still protects the penetration. This is the roofing-first design philosophy made physical, and it's why these attachments carry their leak record.

    The spun-aluminum cone flashing on the QBase comp mount takes the same logic further: no seams, no welds, no joints in the water path at all. Compare that to flat-plate flashings with raised collars — the dominant alternative design — where the collar-to-plate joint is a theoretical leak path forever. In practice both designs work when installed per manual; the difference shows up in decade-two, when sealants are tired and geometry is all that's left.

    4. Structural Math: Layout, Loads, and Pullout

    Attachment layout is structural engineering, and the inputs are site wind speed (ASCE 7), roof zone, snow load, and the rail system's span rating — the attachment count falls out of the rail spans. The worked example below mirrors a real layout from our design desk.

    Design Step Rule / Formula Worked Example (24-module comp shingle job, 120 mph, Exposure B)
    Rail span (from rail span table) Per racking manufacturer's certified table 6.5 ft span (XR100-class rail, interior zone)
    Attachments per rail run Rail length ÷ span + 1 28 ft run ÷ 6.5 ft → 5–6 per run × 4 runs = ~22; tightened edge zones → 24 total
    Uplift demand per attachment Net wind uplift pressure × tributary area ~30 psf edge zone × ~45 ft² tributary ≈ 1,350 lbs demand (design-level; verify with PE)
    Capacity check Tested pullout ÷ safety factor 3,031 lbs tested in Doug fir → adequate margin vs. demand at interior zones; edge zones checked individually
    Edge/corner zone adjustment ASCE 7 zone pressures (edge > interior) Span reduced to ~4–5 ft in perimeter zones — more attachments where uplift peaks
    Rafter engagement Lag into structural member, min. embedment per manual 5/16" lag, 2.5"+ embedment into rafter; pilot 7/32"

    Two points we make to every customer. First: the 3,031-lb pullout number is tested capacity in solid Douglas fir rafters — deck-only attachment is a fraction of that and is not an approved load path. Find the rafters. Second: edge and corner zones govern the layout. ASCE 7 wind pressures at roof perimeters run roughly double the interior field, so the attachment spacing tightens at edges even when the middle of the array could span wider. The racking components guide covers how attachments integrate with rails and clamps downstream.

    5. Competitive Comparison: Quick Mount vs IronRidge vs Unirac

    Feature Quick Mount PV IronRidge (FlashFoot2) Unirac (Flashloc DUO)
    Primary focus Flashed attachments only Full racking + attachments Full racking + attachments
    Seal technology QBlock elevated water seal (patented) Elevated encapsulated seal Triple seal (EPDM)
    Flashing type Spun aluminum cone (no seams) Flat plate with raised collar Diecast aluminum base
    Structural capacity 3,031 lbs pullout (Doug fir) Varies by attachment model 495 lbs uplift (rafter), 135 lbs (OSB)
    Fastener options 2 or 4 lag screws, multiple substrates Single lag bolt 6 wood screws (deck) or 2 (rafter)
    Florida / LA approval Yes (both) Varies Varies
    Warranty 25 yr structural / 5 yr finish 25 years 25 years

    The positioning is complementary more than adversarial: Quick Mount attachments pair with most major rail systems (IronRidge and Unirac rails included), so the common pro move is a Quick Mount attachment layer under whichever rail the job's engineering favors. Where IronRidge FlashFoot2 and Unirac Flashloc Duo are excellent choices inside their own ecosystems, Quick Mount is the attachment specialist — the option when the roof is the hard part: brittle thirty-year-old comp, S-tile in the Southwest, membrane roofs, hurricane country. See the Unirac brand guide and SnapNrack guide for the full-system alternatives.

    6. Installation Notes From the Field

    What our crews do on every flashed-attachment job

    • Locate rafters with a stud finder and confirm with a pilot. Mark every rafter across the attachment rows before lifting a single flashing. Layout follows structure, never the shingle courses.
    • Pilot holes: 7/32" for a 5/16" lag in Doug fir. Full-diameter driving splits rafters and crushes the connection's withdrawal strength; the pilot is not optional.
    • Drive lags with an impact and stop at seat. The lag head seats against the mount — not buried into the flashing seat, not proud. Overdriving cracks the seal collar; underdriving leaves the mount rocking on the post.
    • Course the flashing like a roofer. Upslope edge under the next course, sides shedding over the downslope course, per the manual. A flashing laid on top of the upslope shingle is a funnel, not a flashing.
    • Photograph every attachment before rails go on. This is the leak-warranty documentation set, and it settles disputes years later in about one email.

    On tile jobs specifically: order 5–10% spare tiles before starting, stage broken-tile replacement as part of the install day, and never let the crew walk the valleys. Tile breakage is a certainty; planning for it is the difference between a clean job and a callback. The rooftop installation walkthrough covers the full sequence from layout to commissioning, and our racking systems overview gives the category-level picture.

    6.5 Warranty, Approvals, and the Paper Trail

    Quick Mount's warranty splits the way roofing warranties should: 25 years on the structure, 5 years on the finish. The approval portfolio is the real paperwork asset — Florida product approval including high-velocity hurricane zone requirements, City of Los Angeles approval, and UL 2703 system listings — and the company publishes the test reports behind the pullout numbers, which plan reviewers notice. Our permit packets include the approval numbers on the cut sheets; it turns the structural review of the attachment layer into a checkbox rather than a conversation.

    Documentation Item What It Covers Where It's Used
    Florida Product Approval Wind-uplift compliance incl. HVHZ Florida permits, hurricane-exposed coastal work
    City of Los Angeles approval Structural attachment acceptance LA jurisdictional permits
    UL 2703 listing Mechanical load + bonding path with rail systems Electrical/structural review nationwide
    Pullout test reports 3,031 lbs in Doug fir; substrate-specific values Engineering verification, span-table inputs

    Keep the install photos and the approval documents with the homeowner's records. When the house sells or the roof gets replaced in year twelve, that folder is the difference between a smooth transaction and a forensic argument about who penetrated what, where, and with whose hardware.

    6.6 Common Mistakes We See on Attachment Jobs

    The leak callbacks we've diagnosed over the years trace to a short list, and none of them are the flashing's fault. Flashings coursed over the upslope shingle instead of under it — a funnel built at the factory of haste. Lags driven without pilots, splitting the rafter and halving withdrawal capacity while looking perfect from the roof. Attachments landed in deck because the layout followed the array geometry instead of the rafter map. Sealant smeared on as a substitute for geometry rather than a supplement to it — goop is not a flashing strategy. And on tile, crews walking the valleys and leaving a trail of cracked tiles the homeowner discovers at the first rain. Every one of these is a training issue, not a product issue, and every one is covered in the install manual that comes in the box.

    One last note on sequencing, because it saves crews real hours: lay out and install all attachments on day one, rails and modules on day two. Attachments are the slow, careful, structural part; rails and modules are fast. Splitting the job that way puts the roof-penetration work behind you early, keeps the roof open for the minimum time, and gives the flashing seals a night to settle before the array's weight and wind loads arrive. It's a small scheduling decision that has consistently separated our clean installs from our callbacks.

    It's also worth saying who this brand is for at the purchasing level. Homeowners buying a full solar kit don't need to specify attachment hardware — that's the installer's call. But installers and owner-builders choosing components should understand that the attachment layer is where 25-year roof risk concentrates, and the delta between a specialist attachment and a generic one is a few dollars per penetration against a potential four-figure leak repair. On a 24-attachment job, the upgrade cost is a rounding error on the project. We've never had a customer regret spending it; we've talked to plenty who regretted not spending it.

    7. Frequently Asked Questions

    What makes Quick Mount PV different from the racking brands?

    Specialization. Quick Mount makes only roof attachments and flashings, designed roofing-first: the flashing is the primary component and the mount attaches to it. The QBlock elevated seal sits above the water plane, and the QBase cone flashing is spun seamless aluminum with no joints in the water path. The attachments pair with most major rail systems, so you can combine them with whichever racking the engineering favors.

    QBase Comp Mount or Classic Comp — which for my roof?

    New construction or a re-roof: QBase Composition Mount, whose 12" × 12" cone flashing integrates with fresh shingle courses like a plumbing vent. Existing roof staying in place: Classic Comp Mount, a single-bolt retrofit with the QBlock elevated seal that slides into the existing course. Both carry the same roofing-first seal geometry.

    Will Quick Mount attachments work with my rails?

    Yes — QBase posts accept standard L-feet and rail adapters for the major flush-mount rail systems, including IronRidge XR and Unirac SolarMount. Mixing a Quick Mount attachment layer with another brand's rail is common professional practice, particularly on difficult roofs where the attachment is the critical component.

    How much weight can a QBase mount hold?

    The QBase Composition Mount tests at 3,031 lbs pullout in Douglas fir rafters — far above the per-attachment uplift demand on a properly engineered residential layout. That rating assumes structural-member engagement; deck-only attachment is a small fraction of it and is not an approved load path. Edge and corner roof zones carry higher ASCE 7 uplift and get tighter spacing in the layout.

    Do Quick Mount products meet Florida hurricane requirements?

    Yes — QBase systems carry Florida product approvals (including high-velocity hurricane zone requirements) and City of Los Angeles approval, two of the strictest structural review regimes in the US. Approval documentation is available for permit packets; verify the specific SKU against the current approval listing.

    How do I avoid leaks on a tile roof install?

    Use a tile-replacement flashing system like the QBase Universal Tile Mount so the tile never carries the mount load; the cast base transfers load to the structure below. Order 5–10% spare tiles before starting, replace broken tiles during install rather than after, and keep foot traffic off the valleys. Done this way, tile-roof leak risk drops to composition-roof levels.

    Sources & Standards

    • Quick Mount PV published specifications and test reports: QBase Composition Mount, Classic Comp, Universal Tile, Low Slope (2025–2026)
    • ASCE 7 — design wind/snow loads and roof-zone pressure provisions; UL 2703 (racking and attachment listings)
    • Florida Product Approval and City of Los Angeles approval listings for QBase systems
    • PES Supply internal install records and leak-callback warranty data, 2019–2026

    Related Guides

    Shop Quick Mount PV at PES Supply

    QBase mounts, flashings, and posts in stock for comp, tile, and low-slope roofs — with attachment-layout help on every kit.

    Browse Quick Mount PV

    Related PES Supply guides

    Need Help Sizing This?

    Our team can help you calculate loads, select the right equipment, and source everything from one PO.

    📞 (502) 790-0600

    Email Our Team
    Solar Panels Generators Batteries / ESS EV Chargers Circuit Breakers Charge Controllers

    One PO. One Invoice. Every Trade Covered.

    PES Supply is the distribution arm of PES Global Group — 50,000+ SKUs from 169 authorized brands, LTL freight shipping from Louisville, KY.

    Get a Quote
    Share: X f in @

    Related Articles

    Generac 22kW vs Kohler 20kW Standby Generator: Real Specs

    Generac 22kW vs Kohler 20kW Standby Generator: Real Specs

    Oct 19, 2026
    Best Solar Panels for Cloudy Climates: What Actually Matters

    Best Solar Panels for Cloudy Climates: What Actually Matters

    Oct 02, 2026
    Pallet of boxed solar panels in shrink wrap on a warehouse floor with a liftgate box truck behind

    Solar Panel Pallet Cost, Delivered: $/W Math | PES

    Sep 23, 2026
    Commercial flat-roof solar array with copper grounding lugs bonding aluminum racking rails

    Commercial Solar Grounding BOM: NEC 690.43 | PES

    Sep 23, 2026
    All-black solar panels on a residential shingle rooftop in late afternoon sunlight

    Aptos DNA 460W Panel: Specs, Price & Family | PES

    Sep 23, 2026
    Residential standby generator on a concrete pad beside a brick home with conduit to a wall-mounted transfer switch

    Briggs PowerProtect 13kW Shell + Symphony II ATS | PES

    Sep 23, 2026
    Full wooden pallet stacked with boxed solar panels in shrink film on a warehouse floor with a flatbed liftgate truck behind

    Buying Solar Panels by the Pallet: Pro Guide | PES

    Sep 23, 2026
    Wall-mounted hybrid solar inverter in a tidy residential utility room with metal conduit, red and black battery cables and a subpanel

    Sol-Ark vs GoodWe Hybrid Inverter Guide | PES

    Sep 23, 2026
    Two modern wall-mounted home battery storage units side by side on a clean residential garage wall with conduit and a disconnect

    EG4 Battery vs Tesla Powerwall 3: Honest Comparison | PES

    Sep 23, 2026
    Caribbean-style home in Puerto Rico with a rooftop solar array and a wall-mounted home battery, palm trees and bright sun

    Puerto Rico Solar + Battery Resilience Guide | PES

    Sep 23, 2026
    All-black residential rooftop solar panels with a uniform busbar-free surface on a shingle roof

    AIKO Solar Panels: Price, Specs & ABC Technology | PES

    Sep 23, 2026
    Commercial ground-mount bifacial solar array on light gravel under a clear sky

    Bila Solar AA-530US: Domestic Content Panels & ITC | PES

    Sep 23, 2026
    Gloved hand clamping a split-core current transformer around a conductor inside an open electrical panel

    Accu-CT Split-Core Sensors Explained: 333mV CTs | PES

    Sep 23, 2026
    Floor-standing home battery storage cabinet beside a wall-mounted hybrid inverter in a residential garage

    Big Battery NEXUS 15kWh Explained: Specs & Scaling | PES

    Sep 23, 2026
    Through-the-wall PTAC air conditioner installed on a hotel guestroom wall beneath a large window

    Amana PTAC Sizing Guide: 7,000–15,000 BTU Ladder | PES

    Sep 23, 2026
    Residential standby generator on a composite pad beside a suburban home with an electrician work van in the driveway

    Champion aXis Generator Guide: 8.5kW, 14kW & 22kW | PES

    Sep 23, 2026
    Air-cooled home standby generator on a composite pad with electrician connecting the fuel line

    Generac 7042 & 7172 Explained: /817 and /997 Shells | PES

    Sep 22, 2026
    Modular home battery stack with inverter head and subpanel in a utility room

    Bluetti Buying Guide: AC180P vs AC200PL vs EP900 | PES

    Sep 22, 2026
    All-black residential solar panels on a shingle rooftop at low afternoon sun

    Canadian Solar 445W vs 435W: TOPHiKu6 Model Guide | PES

    Sep 22, 2026
    Portable power station with expansion battery and folding solar panel in a residential garage

    Anker SOLIX Buying Guide: C2000 Gen 2 vs F3800 vs E10 | PES

    Sep 22, 2026
    Electric unit heater mounted high on the wall of a residential garage workshop with metal conduit

    Solar Garage Heater Sizing Calculator | PES

    Sep 20, 2026
    Electrician testing a 240V receptacle with a digital multimeter in a workshop with panel behind

    kWh to Amps Calculator: 120V, 240V & 3-Phase | PES

    Sep 20, 2026
    Home battery storage unit wall-mounted in a garage charging from rooftop solar with hybrid inverter

    Solar Battery Charge Time Calculator | PES

    Sep 20, 2026
    Residential standby generator on a concrete pad beside a house at dusk with interior lights on

    What Can a Generator Run? kW Load Calculator | PES

    Sep 20, 2026
    White residential propane tank beside a standby generator on a concrete pad in a suburban backyard

    Propane Tank Sizing for Generators: Calculator | PES

    Sep 19, 2026
    Residential electric meter on an exterior wall beside the service entrance conduit of a suburban home

    Power Consumption Calculator: kWh & Cost | PES

    Sep 19, 2026
    Galvanized round HVAC ducts and flex duct branching across a residential attic with foil insulation

    Duct Size Calculator: CFM Chart by Room & Ton | PES

    Sep 19, 2026
    Electrician measuring current with a clamp meter on a copper conductor inside a residential breaker panel

    Amps to Watts Calculator: 120V, 240V & 12V | PES

    Sep 19, 2026
    Rooftop solar array with conduit down to an open main service panel showing the backfed PV breaker

    Solar 120% Rule Calculator: Max PV Breaker | PES

    Sep 19, 2026
    Commercial standby generator on a concrete pad with a wall-mounted automatic transfer switch

    kVA to kW Calculator: Power Factor Converter | PES

    Sep 19, 2026
    Open residential breaker panel with 240V double-pole breakers and copper feeders of different gauges

    240V Wire Size Calculator: Breaker & Gauge Chart | PES

    Sep 19, 2026
    Electrician pulling THHN copper conductors into EMT conduit on a hot commercial rooftop

    Ampacity Derating Calculator: NEC 310.16 & Heat | PES

    Sep 19, 2026
    Solar charge controller mounted on utility-room wall with battery bank cables

    Solar Charge Controller Sizing Calculator | PES

    Sep 19, 2026
    Residential rooftop solar array with series-string wiring and aluminum racking

    Solar String Sizing: Max Panels in Series | PES

    Sep 19, 2026
    Rooftop air-conditioning condenser unit with electrical disconnect and conduit whip

    MCA vs MOCP: AC Circuit Sizing Calculator | PES

    Sep 19, 2026
    Open residential breaker panel with labeled double-pole breakers and copper feeders

    Breaker Size Calculator: 125% Rule & Wire Chart | PES

    Sep 19, 2026
    Off-grid hybrid inverter with battery rack and conduit runs in a utility room

    Off-Grid Inverter Sizing: Continuous, Surge & Battery | PES

    Sep 18, 2026
    Electrician's hand holding a circuit breaker in front of an open load center

    Breaker Compatibility Chart: QO vs BR vs QP Panels | PES

    Sep 18, 2026
    Row of residential rooftop solar panels in soft daylight, close-up on glass cells

    Solar Panel Wattage Chart: 400W vs 450W vs 500W+ | PES

    Sep 18, 2026
    Automatic transfer switch with thick copper conductors next to breaker panel

    Transfer Switch Wire Sizing: Ampacity Chart by kW | PES

    Sep 18, 2026
    Torque screwdriver tightening a terminal lug on a copper conductor in a panel

    Lug Torque Chart: NEC 110.14 Terminal Tightness by Size &...

    Sep 18, 2026
    Electrical subpanel with feeder cable and neatly dressed branch circuits

    Subpanel Sizing Guide: Feeder Size, Spaces & Load Calc | PES

    Sep 18, 2026
    Residential rooftop solar installation at golden hour with installer tools nearby

    Solar ROI Calculator: Payback, ITC & 25-Year Savings by S...

    Sep 18, 2026
    Standby generator on concrete pad with automatic transfer switch on house wall

    Transfer Switch Sizing Guide: Amps, Circuits & ATS vs Man...

    Sep 18, 2026
    Standby generator beside a residential propane tank and natural gas line

    Standby Generator Fuel Consumption Chart: NG, Propane & D...

    Sep 17, 2026
    Home battery storage wall unit in a garage powering household circuits

    Solar Battery Backup Runtime Calculator: Hours by Load & ...

    Sep 17, 2026
    Service entrance mast and meter base on a residential exterior wall

    Service Entrance Cable Size Calculator: 100A/200A/400A Se...

    Sep 17, 2026
    Green-insulated copper grounding conductors bonded to a ground bar in a panel

    Ground Wire Size Chart: NEC 250.122 EGC Sizing by Breaker...

    Sep 17, 2026
    Thick red and black battery cables with crimped lugs on a battery bank rack

    Battery Cable Size Chart: 12V/24V/48V Inverter & Bank Cab...

    Sep 17, 2026
    Level 2 EV charger wall-mounted in a residential garage with dedicated circuit

    EV Charger Circuit Sizing: NEC 625 Breaker, Wire & Load C...

    Sep 17, 2026

    Get Price Drops & Product Releases

    Weekly digest for installers and project managers — price drops, new stock, NEC code updates.

    Portlandia Electric Supply